Hi Flow

PATIENT

OPERATING

INSTRUCTIONS

Stroller

H I F L O W S T R O L L E R

Содержание HI Flow

Страница 1: ...Hi Flow PATIENT OPERATING INSTRUCTIONS Stroller H I F L O W S T R O L L E R...

Страница 2: ...ithin five feet of electrical appliances especially stoves heaters toasters and hair dryers Hi Flow Stroller Keep your unit in a well ventilated area In the event of an accidental tip over immediately...

Страница 3: ...1 Patient s Records Patient s Name Prescribed Oxygen Flow Setting Doctor s Telephone Number Distributor s Name Person to Contact Distributor s Emergency Telephone Number Special Instructions...

Страница 4: ..._ 3 Controls _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _4 5 Filling Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 9 Operating Instructions _ _ _ _ _ _ _ _ _ _ _ _ _ 10 14 Additional Information _ _...

Страница 5: ...uctions for using the Hi Flow Stroller Refer to the POI supplied with the stationary unit for its operation The Liberator is the larger container and is intended for stationary use You may take oxygen...

Страница 6: ...ontrols 1 Electronic Liquid Level Gauge 2 Flow Control Knob 3 Oxygen Tube Connector 4 Vent Valve 5 Fill Connections see next page for QDV Identification 6 Carrying Strap with Shoulder Pad 7 Condensati...

Страница 7: ...5 Hi Flow Stroller Portable Connector Stationary Connector QDV Style CAIRE LINCARE CRYO2 LIFE OX PENOX TAEMA PB Side Fill UC SF Locking TF Locking TF Push on Quick Disconnect Valve QDV Identification...

Страница 8: ...ep 6 page 9 To Fill the Top Fill Hi Flow Stroller 1 Clean the fill connectors on both the stationary and the Hi Flow Stroller with a clean dry lint free cloth Caution The fill connectors must be dry b...

Страница 9: ...w Stroller and stationary unit to freeze together 2 Make sure the flow control is in the off 0 position 3 Make the Hi Flow Stroller fill connector in the upright position to the stationary connector 4...

Страница 10: ...oxygen escaping do not worry The hissing sound you hear is perfectly normal Note Liquid level gauge readings are most accurate 30 seconds or more after the Hi Flow Stroller is filled 7 You may also s...

Страница 11: ...sing the valve at the first sign of liquid discharge does not fill the Hi Flow Stroller as completely but saves liquid oxygen 9 For the push on style connectors push the release button down until the...

Страница 12: ...Flow Stroller clockwise until the prescribed flow rate numeral is visible in the knob window and a positive detent is felt Warning Out of specification oxygen flow will result if the flow control knob...

Страница 13: ...mat 00 00 Note The Nominal times are for ideal conditions i e maximum fill exact flow rates good loss rate unit not being moved etc These times are the maximum expected Note Your individual results wi...

Страница 14: ...ad the arc of LEDs which indicate contents level Caution The Hi Flow Stroller is empty if only the first LED on the far left is lit If the Low Battery indicator lights up when the button is depressed...

Страница 15: ...possibility of excessive moisture icing build up it is recommended that the Hi Flow Stroller remain idle for 1 hour after use to decrease moisture buildup Hi Flow Stroller Due to the higher flow rates...

Страница 16: ...up Unzip soft feature case access door at bottom of unit Remove the pad and wring out any absorbed moisture Allow the pad to dry completely before replacing it back in the unit Note If heavily soiled...

Страница 17: ...sing procedure see applicable service manual WEEE and RoHS This symbol is to remind the equipment owners to return it to a recycling facility at the end of its life per Waste Electrical and Electronic...

Страница 18: ...16 Patient Notes...

Страница 19: ...e v C 1 0 1 0 M D D R e p re s e n t a t i v e M e d i c a l P ro d u c t S e r v i c e s B o r n g a s s e 2 0 3 5 6 1 9 B r a u n f e l s G e r m a n y B a l l G r o u n d G A 3 0 1 0 7 U S A w w w...