background image

CAHORS 

CS 60022 - 46003 Cahors cedex 9 - France 
Tél. +33 (0)5 65 35 82 20 Fax + 33 (0)5 65 35 82 52 

www.groupe-cahors.com

 

 

The MSU range allows cascade or standalone operation. 

 

 

Definition of standalone mode: 

 

Multiswitch used alone or at the end of the cascade. 

This mode loads the outputs of the Multiswitch with 75-ohm terminations 

 

 

Definition of cascading mode: 

 

Mode allowing the addition of multiswitches in cascadable mode. 

The outputs are not loaded 

 

Amplification before injection in the multiswtich / column 

 

 

Multiswitch (acceptors of high input levels). If LNB output signals or filter output signals are 

sufficient, they will need the amplifiers. 

 

Active for all multiple switches: Maximum input level of 95 dBμV 

 

Satellite for all multiswitch: Maximum input level of 100 dBμV 

 

 

Column feed, remote power supply 

 

The DC case and LNB power supply is via any satellite cascadable output from the switch (main 

satellite). 

 

The power supply without receiver does not make it possible to remote power the multiswitch 

nor the heads, nor a preamplifier of reception by terrestrial input. It is obligatorily a 12 V 

external power supply. 

 

The remote feeding does not go up by the terrestrial trunk. 

It goes back only by the satellite trunk 

 

System performance 

 

The system can operate in active or passive mode for the terrestrial. 

 

See last page for details of losses 
 

The trunk losses are to be taken into account when using more than one multi-switch in the 

columns. 

Содержание MSU Series

Страница 1: ...T l 33 0 5 65 35 82 20 Fax 33 0 5 65 35 82 52 www groupe cahors com GAMME MULTISWITCH MSU MULTISWITCH MSU SERIES Multiswitch universel autonome ou cascadable Universal multiswitch standalone or casca...

Страница 2: ...le produit dans un lieu sec sans infiltration ni condensation d eau Si un liquide tombe accidentellement dans le boitier d brancher l alimentation Ne pas exposer le produit une source de chaleur solei...

Страница 3: ...es multiswitch Niveau d entr e max de 95 dB V En Satellite pour tous les multiswitch Niveau d entr e max de 100 dB V Alimentation de la colonne t l alimentation terrestre Le passage DC de boitier en b...

Страница 4: ...iswitch est correctement aliment Led de presence de la t l alimentation antenne 12V Si une antenne s che est branch e la t l alimentation se d sactivera automatiquement et la LED s teindra Le bouton A...

Страница 5: ...6003 Cahors cedex 9 France T l 33 0 5 65 35 82 20 Fax 33 0 5 65 35 82 52 www groupe cahors com Exemple de montage Alimentation externe 12 V Switch mode cascadable Switch mode autonome Switch mode casc...

Страница 6: ...oisture Install the product in a dry place without infiltration or condensation of water If a liquid accidentally falls into the case unplug the power supply Do not expose the product to a source of h...

Страница 7: ...need the amplifiers Active for all multiple switches Maximum input level of 95 dB V Satellite for all multiswitch Maximum input level of 100 dB V Column feed remote power supply The DC case and LNB po...

Страница 8: ...owered Switch Operation The Autonomous Cascadable button allows the following actions Autonomous mode to activate when you have a single switch It is to be activated also on the last switch of a colum...

Страница 9: ...6003 Cahors cedex 9 France T l 33 0 5 65 35 82 20 Fax 33 0 5 65 35 82 52 www groupe cahors com Installation example Switch mode cascadable External Power supply Switch mode standalone Switch mode casc...

Страница 10: ...ply Cascadable PASSIF 0mA ACTIF 135mA Terminal PASSIF 55mA ACTIF 175mA SATELLITE Consumption From The Receiver 40 mA References MSU Model Input Output numbers Dimensions L x l H 4 cm 0145300R13 MSU 50...