TOTAL LITE Revision 1
SERVICE MANUAL FOR INNOVATION
TOTAL LITE
Single-Cup Brewer
59
9.2
Brewer Assembly
Preventive Maintenance (PM): Yearly or every 25,000 coffee cycles
The brewer is the heart of the equipment and is responsible for the taste of the beverage. It needs to
be replaced or refurbished to maintain the quality of the beverages served. We recommend having
your brewer assembly replaced every 25,000 coffee cycles.
Contact 1-800-561-6162 for parts and additional information.
Inspection
The following are signs of the vacuum is not functioning adequately and that your brewer may be due
for preventive maintenance:
·
if the seal is damaged;
·
if air gets into the cylinder and creates bubbles in the coffee;
·
if there are coffee grounds in the delivered product;
·
if the spent coffee grounds remain wet.
Preventive Maintenance
Screen and Seal
Cylinder
Teflon Seal
Brew
Chamber