Initial Setup
3.6
Water Line Connection
This equipment must be installed in compliance with applicable Federal, State,
Provincial and/or Municipal plumbing codes having jurisdiction.
Make sure that the equipment is unplugged before proceeding with the water supply
installation. Also verify that the incoming water pressure is greater than 20 psi and
no more than 80 psi.
1.
Prior to installing the equipment, flush out the water line by running approximately 1 gal. of water into
a pail.This will ensure no sediment from a new installation can get in the equipment;
2. The incoming water supply should have a shut-off valve connected in-line. Water supply should be a
plastic 1/4” or 3/8” outside diameter dedicated line branched off a larger supply line;
3.
Make sure your water source is turned off. Secure the inlet fitting firmly onto the inlet valve Do not
overtighten;
4.
Make sure the equipment is unplugged. Connect the water line to the quick connect inlet fitting;
5. Turn the water valve on, sending water to the brewer. If there are any leaks, tighten connections to
stop leakage.
This procedure does not take into consideration the installation of a water filtration system.
Please refer to the water filter manufacturer installation instructions and incorporate them into
the above procedures.
Water inlet