Initial Setup
3.4.2
Adjusting the Tank Overflow Float
It is important to verify that the float is positioned properly in the overflow cup because it can move
around in transportation. If this float is not properly in place the switch will not be activated and the unit
will automatically shut down sensing an overflow situation.
It is important to verify that the Overflow cup is in place with the highest side in front and secured well
with the green tape. If you need to remove this cup, please make sure that you replace it with the
highest section facing the front and the overflow tube in the cup. Fasten it in place with tape. This will
ensure that the float will “float” and will activate the overflow switch if a problem accurs.
Cup
Hole in the
exit of the
tube
Location in the brewer