INNOVATION TOTAL LITE Rev. 1 2021-10
www.cafection.com 800-561-6162
42
SERVICE & INSTALLATION MANUAL for Cafection’s Total Lite
S
e
rv
ic
e Mo
d
e
7. The Liquids and Ingredients interface is used to customize the quantity of each ingredients of the drink.
8. This button is used to reset all recipes to default settings.
9. This button is used to fix a lost or corrupted recipe by resetting it to default settings.
10. Discard any changes done in the current modification.
11. This button is used to save any changes to the current recipe. Any unsaved changes will be lost.
"
Liquids and Ingredients
"
Interface
All values used for the recipes are time values. The water quantity values represent the
amount of time the dispensing water valve is opened. The coffee or soluble quantity
values represent the amount of time the motor is running.
20 units = 1 second.
The right section of the numeric keypad indicates
an estimated conversion
of the value in units to a
milliliter (ml) and to a US ounce fluid (oz) for liquids, or in grams (g) for the ingredients.
A. This table is used to set the quantity of dry ingredients for each size and strength of the drink
B. This dropdown menu is used to select the default coffee blend used for the recipe (if applicable).
C. This button is used to allow blend choice by the customer on some recipes.
D. This table is used to set the quantity of water required to brew the recipe. The recipe’s brew cycle is
automatically selected by the software.
E. Select the close button to exit the current recipe Liquids and Ingredients interface and go back to the
Recipes Information sub tab.
E
A
B
C
D
1
2
7
8
9
10
11
3
4
5
6