ENCORE LITE Rev. 3 05/2018
www.cafection.com 800-561-6162
64
SERVICE & INSTALLATION MANUAL for Cafection's Encore Lite
C
le
an
in
g
an
d
San
it
iz
in
g
7.8.3 Soluble Canisters
Soluble Whipper Assembly
Frequency: weekly or every 200 cycles
If there is product accumulation, remove the soluble
whipper assembly for manual cleaning under hot
water.
1. Remove the tube from the base.
2. Lift the funnel. Remove the whipper chamber and
the propeller, then twist off the whipper base.
3. Clean all parts and gaskets with hot water. Use
the small brush for tubes, if necessary.
4. Air dry completely.
5. Reinstall all parts in reverse order.
6. Order a large beverage of each soluble to ensure
that all parts and switches are working properly.
Soluble Canisters
Frequency: monthly or every 1,000 cycles
It is recommended to remove, empty and clean the soluble canisters every month to avoid
powder to accumulate on the walls of the canisters and alterate the beverages quality.
1. Open the brewer's door.
2. Remove the top lid.
3. Lift the plastic funnel and its cover out of the
machine.
4. Pull the canisters out of the brewer to disengage
them from the motor and transmission.
5. Clean and sanitize under hot water and air dry
completely.
6. Reinstall all parts and reload products in the
canisters.
7. Order a large beverage of each soluble to confirm
that all parts and switches are working properly.
If there is no funnel (previous version):
1. Open the brewer's door.
2. Remove the bean hopper back plate
(2 screws), the bean hopper, the top
lid and the plastic hood (5 screws).
3. Gently lift the canisters and pull them
out to disengage them from the
motors and transmissions.
4. Clean and sanitize under hot water
and air dry completely.
5. Reinstall all parts and reload products
in the canisters.
6. Order a large beverage of each
soluble to confirm that all parts and
switches are working properly.