SERVICE & INSTALLATION MANUAL for Cafection's Encore Lite
3.9
Water Temperature
This equipment has a coffee brewing setpoint of 200 °F water temperature to ensure a consistent
beverage quality. There is a +/- 2 °F tolerance.
This value represents an average and will not correspond to the temperature of a manual
measurement. The actual water temperature fluctuates because cold water is added to the
tank after every beverage delivery and time is needed to heat the new incoming water up to the
setpoint.
Water’s brewing temperature can also be taken manually by ordering a cup of hot water and
measuring its temperature with a thermometer. There may be a slight difference from the tank
reading. This is normal.
If the temperature measurements show a large temperature differential, verify that the tank is clean
and not obstructed by mineral deposits and scale.
Unit Safety Measures
In the event of a temperature probe failure, water in the tank might start to boil. This will cause it to
overflow into the overflow cup and will automatically shut the machine off. However, the computer
screen will remain active (ON).