background image

                           

Instructions for using HoloLens with VimedixAR™

 

 

 

 

 

 

 

 

 

 

 

 

 ©2017 CAE 
905K800022 v4 

 

 

 

 

 

 

 

 

 

 

VimedixAR: Getting Started  

Thank you for choosing the VimedixAR add-on module, the latest innovation for your Vimedix ultrasound simulator. 
Using the Microsoft HoloLens, VimedixAR allows you to see Augmented Reality in the form of 3D holograms that 
appear directly on the Vimedix manikins.  
The following guide contains links to videos that will show you how to easily start using VimedixAR to enhance your 
Vimedix learning experience.  

Getting Started with the Microsoft HoloLens  

Please use the following links for instructions about the general use, maintenance and functionalities of the 
Microsoft HoloLens: 

 

 

Instructions for using HoloLens with VimedixAR™ 

CAE Vimedix Augmented Reality Comes Alive

 

Freed from its two-dimensional environment inside a monitor, our VimedixAR™ ultrasound simulator leaps to life, 
displaying anatomy you can enlarge, turn, rotate or command to return into its manikin body so you can view the 
interrelatedness of its structures. Witness in real time how the ultrasound beam cuts through the human 

anatomy. 

Содержание VimedixAR

Страница 1: ...VimedixAR to enhance your Vimedix learning experience Getting Started with the Microsoft HoloLens Please use the following links for instructions about the general use maintenance and functionalities...

Страница 2: ...tps support microsoft com en us help 12644 Start menu and finding your apps https support microsoft com en us help 12638 Spaces on HoloLens https support microsoft com en us help 13760 hololens spaces...

Страница 3: ...INTERFACE 11 INTERACTIVE PANEL 11 Ultrasound Panel 17 HOLOGRAM CONTROLS 18 SHARED EXPERIENCE MODES 20 CALIBRATION PROCEDURE 21 Calibration by Tag 21 Calibration by Gaze 21 Fine Tuning Your Calibratio...

Страница 4: ...Instructions for using HoloLens with VimedixAR 4 2017 CAE 905K800022 v4 ESTABLISHING A NETWORK CONNECTION 46 CHECKING FOR VIMEDIXAR UPDATES 47 UPDATING VIMEDIXAR 48...

Страница 5: ...the following sequence Beginning with the router computer and HoloLens powered off 1 Turn on the router Power on the Router 2 Connect the network cable between the bottom port of the computer and any...

Страница 6: ...WIFI network by following the steps below 1 Bloom to view the Start menu 2 Select the Settings icon in the Start menu Settings Icon 3 Air tap the Settings window to anchor it in place 4 Select the Ne...

Страница 7: ...ng around This directs the device to return visual feedback on its spatial mapping drawing green triangles on the surfaces it knows about Note The HoloLens continuously tracks its surroundings to main...

Страница 8: ...rting a VimedixAR Simulation with Microsoft HoloLens To start a VimedixAR simulation with the HoloLens 1 Select the VimedixAR app in the Start menu Vimedix App Icon 2 Move the VimedixAR Startup window...

Страница 9: ...h VimedixAR 9 2017 CAE 905K800022 v4 3 Adjust your HoloLens so that all four corners of the FitBox are visible VimedixAR Start Simulation FitBox 4 Begin the simulation by air tapping or using the voic...

Страница 10: ...imedixAR simulation with the HoloLens 1 Bloom to return to the Start menu 2 Select the Remove icon in the upper right corner of the VimedixAR Startup window to exit the VimedixAR simulation VimedixAR...

Страница 11: ...ce is divided into three main sections Interactive Panel Ultrasound Panel Hologram Controls VimedixAR User Interface Interactive Panel The Interactive Panel is controlled by the following tabs along i...

Страница 12: ...al Patient 3 and the Shared Experience Mode e g Individual Instructor or Student when the Information tab is selected and there are no warnings to be displayed Information Tab Interactive Panel Note R...

Страница 13: ...each Shared Experience Mode in VimedixAR If your Shared Experience Mode is Individual you can gain control over the other HoloLens by selecting the Instructor option If your Shared Experience Mode is...

Страница 14: ...e Interactive Panel also provides you with the option to calibrate the position of the Hologram Manikin relative to the Physical Manikin by tag or by gaze Calibration by tag is started by selecting th...

Страница 15: ...Find Fluids exercises To begin the setup that is required prior to starting the Region Scan or Find Fluids exercise select the Start button that is directly below the description of the respective exe...

Страница 16: ...instructions You can end the IPD Calibration prematurely with the bloom gesture in which case your IPD will not be updated To start the Shared Demo select the Shared Demo button on the Interactive Pan...

Страница 17: ...active Panel Select the Help tab using the voice command Vimedix Help or with the gaze and air tap gestures Please refer to the Voice Commands section of the user guide for more information about when...

Страница 18: ...you are prompted to tap and hold the UI to drag it to your desired location Note The UI will be boxed in orange when it is in your grasp and boxed in blue when it is not The Adjust Menu icon is an op...

Страница 19: ...layers above the Physical Manikin The Raise Anatomy button raises the anatomy that is selected in the Structures Visibility menu on the Vimedix system above the Physical Manikin such that the anatomy...

Страница 20: ...well as perform a Shared Demo for them The Local Demo option is disabled for the Instructor An Instructor can become an Individual user by selecting the Individual option on the Interactive Panel und...

Страница 21: ...right ear of the Physical Manikin with the arrow facing the head When the HoloLens recognizes the tag it places a holographic image of the tag on top of it with the Hologram Manikin not far You must...

Страница 22: ...irection of its head Vimedix Move Caudal Moves the Hologram Manikin one centimeter in the direction of its feet Vimedix Apply Stand Inclines the Hologram Manikin at a 45 angle on its left side to matc...

Страница 23: ...t the stand control of the 3D Calibration Widget to incline the Hologram Manikin at a 45 angle on its left side to match the inclination of the Physical Manikin when it is configured with both stands...

Страница 24: ...horough FAST Focused Assessment with Sonography for Trauma ultrasound examination in the shortest time possible The Region Scan exercise is only performed by the Instructor and is observed by the Stud...

Страница 25: ...ect one or more regions to scan To scan all regions select the All option above the Right Upper Quadrant option The Region Scan Parameters also include the option to enable visual aids representing th...

Страница 26: ...e button at the bottom of the Interactive Panel with the gaze and air tap gestures The Interactive Panel then displays the Region Scan Results which include total time total distance traveled cm total...

Страница 27: ...protocol regions will also appear at this point regardless of whether you enabled them or not during the setup of the Region Scan exercise Use your gaze to select a region to view its name and the pe...

Страница 28: ...col regions they selected prior to starting the exercise you will see them on the Hologram Manikin when the Exercise Status is In Progress When the Exercise Status is Completed the Interactive Panel d...

Страница 29: ...ayed in simulation once you have completed the Free Fluids exercise To begin the setup that is required prior to starting the Find Fluids exercise select the Start button that is directly below the de...

Страница 30: ...e and air tap gestures The timer starts when the Find Fluids exercise is started the timer is visible at the top of the Interactive Panel Find Fluids Interactive Panel Instructor When you finish locat...

Страница 31: ...ram Manikin representing the percentage of a region that was successfully scanned Note Green points indicate scanned areas and red points indicate non scanned areas The visual aids representing the fr...

Страница 32: ...visual aids representing the free fluid in the regions they selected prior to starting the exercise you will see them on the Hologram Manikin when the Exercise Status is In Progress When the Exercise...

Страница 33: ...y are connected to Vimedix The Shared Demo gives the Instructor the opportunity to demo the features of VimedixAR To start a Shared Demo the Instructor must select the Shared Demo button on the Intera...

Страница 34: ...asound beam cut plane only the Ultrasound Panel displays the ultrasound image Note Only the anatomy that is selected in the Structures Visibility menu on the Vimedix system is visible when the Cut Pla...

Страница 35: ...v4 Shared Demo Interactive Panel Note Only the Instructor can select each item with the gaze and air tap gestures or with the voice commands listed in the table above The Instructor selects the Exit...

Страница 36: ...Structures Visibility menu in Vimedix even if you are connected to Vimedix Demo Item Voice Command Description FitBox Vimedix Step 1 Displays the FitBox in your field of view Anatomy Vimedix Step 2 Di...

Страница 37: ...2017 CAE 905K800022 v4 Local Demo Interactive Panel Demo items are selected with the gaze and air tap gestures or with the voice commands listed in the table above To exit the Local Demo select the E...

Страница 38: ...and towards the right Please refer to the Hologram Controls Shared Demo and Local Demo subsections of the user guide to learn when these zoom and rotation gestures are unlocked during a VimedixAR simu...

Страница 39: ...Counterclockwise Increase Zoom Decrease Zoom voice command can only be executed when the anatomy is raised Calibration Move Lateral Left Move Lateral Right Move Anterior Move Posterior Move Cranial Mo...

Страница 40: ...ffect if the Vimedix Hide Menu voice command was used beforehand it should not be confused with the Vimedix Face Me voice command Menu Configuration Help Configures the Interactive Panel to display th...

Страница 41: ...ectional view of the hologram anatomy based on the position of the ultrasound beam cut plane Probe Beam Configuration Remove Cross Section Removes the cross sectional view of the hologram anatomy Prob...

Страница 42: ...the different anatomical systems into layers above the Physical Manikin Anatomy Configuration Collapse Layers Collapses the layers of the different anatomical systems but configures the collapsed ana...

Страница 43: ...e HoloLens are not connected to the Vimedix WIFI network Refer to the Connecting and Starting the Microsoft HoloLens section of the user guide for more information on how to verify this connection You...

Страница 44: ...This warning message will appear when Vimedix is turning ON or OFF When Vimedix is running make sure to load one of the following pathologies that are supported by VimedixAR in Vimedix Normal Patient...

Страница 45: ...s Whenever a software update for VimedixAR is released during the warrantee period you will be notified via email phone or standard mail It is important to note that the VimedixAR application does not...

Страница 46: ...ap the Settings window to anchor it in place 4 Select the Network Internet icon Settings Window Network and Internet Icon 5 Connect to a WIFI network with internet capabilities If required enter the p...

Страница 47: ...anchor it in place 4 Select the User icon to the left of the search bar User Icon 1 Select the Downloads and updates option 2 Select the Check for updates button Note it may take a few minutes for th...

Страница 48: ...verify that these will not interfere with VimedixAR functionality Reestablish Vimedix Network 1 Close all open windows by air tapping on the Remove icon 2 Bloom to show the Start menu 3 Select the Set...

Страница 49: ...ates and Latin America Monday Friday from 7 00 a m to 6 00 p m ET Phone 1 866 462 7920 Email customerservice caehealthcare com Customer Service Canada Monday Friday from 8 00 a m to 5 00 p m ET Phone...