IMPORTANT INSTRUCTIONS

WARRANTY

TECHNICAL SPECIFICATIONS

TECHNICAL SUPPORT

CONTROL

INSTALLATION

TEP402DW

1.  Connect the ‘L1’ thermostat wire to the live supply wire.

2.  240 V: Connect the ‘L2’ thermostat wire to the other live supply wire  

 

and

 the other live heater wire. 

120 V:  Connect the ‘L2’ thermostat wire to the neutral supply wire   

and

 the neutral heater wire.

3.  Connect the ‘Load’ thermostat wire to the live heater wire.

TEP302DW, TEP362DW

1.  Connect the 

black

 ‘L1’ thermostat wire to the live supply wire.  

2.  240 V: Connect the 

red

 ‘L2’ thermostat wire to the other live supply wire. 

120 V: Connect the 

red

 ‘L2’ thermostat wire to the neutral supply wire.

3.  Connect the 

black

 ‘Load’ wire to the live heater wire.

4.  240 V: Connect the 

red

 ‘Load’ thermostat wire to the other heater wire. 

120 V: Connect the 

red

 ‘Load’ thermostat wire to the neutral heater wire.

The thermostat should be mounted after the wiring connections have been 

connected.

1.  Remove the small screw at the bottom of the thermostat using a  

Philips #1 screwdriver.

2. 

Carefully insert a small flat head screwdriver in the slot between the 

faceplate and the gray bezel, and gently pry apart.

3.  Position the thermostat over the junction box, and secure it using the two 

supplied screws. 

Note: For models TEP302DW and TEP362DW, the protruding part from 

the back will be recessed into the junction box

4.  Remove the plastic battery insulating tab inside the thermostat.

5.  Reinstall the faceplate and insert the previously removed screw.

6. 

Remove the protective film before use.

In case of loss of power, the thermostat will retain these settings. Follow the 

instructions below to change the settings.

Language

Select your language preference (English or French):

1. Press 

+

 and 

-

 at the same time to enter the setup.

2. Press 

M

. The days of the week will flash in the current language setting.

 

The letters 

M T W T F S S

 indicates the 

English

 setting. 

L M M J V S D

 

indicates the 

French

 setting.

3. Use 

+

 or 

-

 to change the current setting.

4. The display will blink for 6 seconds before returning to the main screen.

Temperature Display

Select your preferred temperature display:

1. Press 

+

 and 

at the same time to enter the setup.

2. Press 

M

 twice. 

°C

 or 

°F

 will flash. 

3. Press 

+

 or 

-

 if you wish to change the temperature display.

4. The display will blink for 6 seconds before returning to the main screen.

Heat Mode

Select the mode that applies to your heater: If the incorrect setting is chosen, 

your heater may short cycle or hold an inconsistent temperature.

1. Press 

+

 and 

at the same time to enter the setup.

2. Press 

M

 3 times.   or 

 will flash. 

3. Press 

+

 or 

-

 to select the option suitable for your heater.

 

 Select 

 for fan-forced heaters or 

 

for convection heaters (including 

baseboard heaters).

4. The display will blink for 6 seconds before returning to the main screen.

Time and Day

Set the current time and format.

1. Press 

+

 and 

at the same time to enter the setup.

2. Press 

M

 6 times. 

12hr

 or 

24hr

 will flash. 

3. Use 

+

 or 

-

 to change the time format.

4. Press 

ü

 to confirm. The 

hour

 digits will flash. 

5. Adjust the hour using 

+

 or 

-

6. Press 

ü

 to confirm. The 

minute

 digits will flash. 

7. Adjust the minutes using 

+

 or 

-

.

8. Press 

ü

 to confirm. The currently set day of the week will flash.

9. Use 

+

 or 

-

 to select the current day of the week. 

10. Press 

ü

 to confirm. 

Program Setup

To set the program:

1. Press 

M

 to enter the program setup. 

You will need to program the first event; Wake Up [

] for the 5 weekdays. 

The two ‘hour’ digits will flash. 

2. Adjust the hours using 

+

 or 

-

.

3. Press 

ü

 to confirm. The two ‘minute’ digits will flash. 

4. Adjust the minutes in 15-minute intervals using 

+

 or 

-

.

5. Press 

ü

 to confirm. The set point temperature will flash. 

6. Adjust the event temperature set point using 

+

 or 

-

.

7. Press 

ü

 to confirm. The Wake Up event is now programmed. 

8. Repeat steps 3-8 to program the remaining events: Away, Return, and 

Sleep to complete the weekday setup. Once the weekday setup is 

completed, you will continue to the programming of events for the weekend. 

To exit program setup at any time, wait 10 seconds for the thermostat to 

return to the main screen.

SETUP

WIRING INSTRUCTIONS

MOUNTING THE THERMOSTAT

PROGRAMMING

QUICK MODES

FUNCTIONS

DISPLAY

Time

Time format

Standby (OFF)

Days of the week

(English/French)

Heat Mode

(Fan, Convection/

Baseboard)

Quick Modes

(Early Start, Vacation, Comfort, Economy)

Lock

Temperature 
Display
Temperature

Programmed Event
(Wake Up, Away, 
Arrive, Sleep)

TEP302DW

TEP362DW

TEP402DW

Max. load  
(at 120/240 V)

1500 W / 3000 W

1800 W / 3600 W

2000 W / 4000 W

Max. Amps

12.5

15

16.67

Wiring

Double pole, 4 wire

Double pole, 4 wire

Single pole, 3 wire

Electrical Rating

120/208/240 V 50-60Hz

Heater Compatibility

Compatible with fan-forced or convection heaters 
and baseboards

Temperature range

Programmable 5 °C - 30 °C (41 °F - 86 °F)
Readable -40 °C - 70 °C (-40 °F - 158 °F) 
LCD may degrade at 0 °C (32 °F)

Software

Class A

Certification

cULus

Impulse Voltage

2500

Pollution Degree

PD2

If the thermostat is deemed defective within 3 years of the 

original date of purchase, Cadet will repair or replace the 
product at its discretion. 
Warranty is void in case of damage incurred from improper use 
or installation. 
See http://cadetheat.com/product-warranty for details.

This product must be installed by a qualified electrician. 
In order to avoid fire, shock or death, shut off power supply at the circuit 

breaker or fuse before wiring.
Before you begin:

• Verify that the heating appliance that is being connected is within the 

specified load range.

• 

Confirm voltage is within the device rating.

• For wiring, use copper conductors only.
• 

Mount on a certified electrical box only.

Keep this user’s guide in a safe place for future reference.

Use quick modes to quickly and easily change the temperature using the 

following presets:

 Early Start 

When the ‘Early start’ function is active, the thermostat will start heating the 

room 30 minutes earlier than the set time for next programmed event.

 Vacation 

This mode will set the temperature at 10 °C (50 °F) to conserve energy while 

you are away for long periods of time.

 Comfort 

This mode is used to slightly increase the temperature across all programmed 

events to maintain a more comfortable temperature.

 Economy

This mode is used to slightly decrease the temperature across all 

programmed events to save energy.

To enable/disable a quick mode:

1. Press and hold 

M

 for 3 seconds. All of the quick mode icons will appear.

2. Use the 

+

 or 

-

 to scroll through icons until the desired one is blinking. 

3. Press 

ü

 to turn the selected quick mode on or off.

More than one quick mode can be active at the same time. See the chart 

below for compatibility.

Thank you for your purchase! Question or problem? Let us solve it 

with a single phone call, email or online chat! We’ll save you a trip 

back to the store!

Phone:  855.223.3887 (from US)

 

800.668.6663 (from Canada)

email: [email protected]

Live chat: cadetheat.com (contact us)

Cadet Customer Service

7216290100R01

To heater

To heater

L2 or 

L2 or 

Neutral

Neutral

L2 or 

L2 or 

Neutral

Neutral

L1

Load

Load

L1

L2

L1

To power supply

To power supply

I

n keeping with our policy of continuous product 

improvement, we reserve the right to make 
changes without notice.

© 2020 Glen Dimplex Americas

Insert small 

flat head 

screwdriver 

here

Early Start

Comfort

Economy

Vacation

Setting the Temperature

The display will show the ambient temperature, except during temperature 

adjustment, in which case it will show the set temperature. To adjust the set 

temperature:

1. Press 

+

  or 

-

 to select the desired temperature.

2. The display will blink for 6 seconds before returning to the main screen.

When the temperature is changed from the scheduled set point for the current 

event, 

HOLd

 will appear at the top of the screen, where the time is normally 

displayed. This indicates that a temporary hold has been set. The next 

scheduled event will override this temperature change.

Lock Function

Use the lock function to prevent the settings from being changed inadvertently.

1. Press 

+

 and 

-

 at the same time.

2. Press 

M

 5 times. The   icon will blink.

3. Press 

+

 or 

-

 to toggle it on and off.

 

 The   icon blinks fast to indicate that it is enabled, and blinks slow to 

indicate that it is disabled. 

4. The display will blink for 6 seconds before returning to the main screen.

The   icon will remain visible to indicate that the lock function is enabled.

To disable, press and hold 

+

 and 

-

.

Standby (OFF)

Use the standby function to turn the heat off indefinitely.

1. Press 

+

 and 

-

 at the same time.

2. Press 

M

 4 times. The   icon will blink.

3. Press 

+

 or 

-

 to toggle it on and off.

 

 The 

 icon blinks fast to indicate that it is enabled, and blinks slow to 

indicate that it is disabled. 

4. The display will blink for 6 seconds before returning to the main screen.

When enabled, only the   icon will remain visible on the screen.

To disable, press and hold 

+

 and 

-

.

Factory Reset

If thermostat settings need to be adjusted significantly, the thermostat can be 

reset.

•  Press and hold the 

M

 for 10 seconds. The display will flash and be reset to 

the thermostat’s original configuration.

Firmware Version

To display the firmware version:

1. Press 

+

 and 

at the same time.

2. Press 

M

 7 times. The firmware version will be displayed where the time 

is typically located.

3. The display will return to the main screen after a 6-second delay.

TEP SERIES

TEP SERIES

PROGRAMMABLE ELECTRONIC 

PROGRAMMABLE ELECTRONIC 

LINE VOLTAGE THERMOSTAT

LINE VOLTAGE THERMOSTAT

USER’S GUIDE

USER’S GUIDE

Load

Load

L1

L2

Moderate pressure must be applied to the center of each button to 

operate

.

Содержание TEP Series

Страница 1: ...fire shock or death shut off power supply at the circuit breaker or fuse before wiring Before you begin Verify that the heating appliance that is being connected is within the specified load range Confirm voltage is within the device rating For wiring use copper conductors only Mount on a certified electrical box only Keep this user s guide in a safe place for future reference Thank you for your p...

Страница 2: ...o the neutral heater wire The thermostat should be mounted after the wiring connections have been connected 1 Remove the small screw at the bottom of the thermostat using a Philips 1 screwdriver 2 Carefully insert a small flat head screwdriver in the slot between the faceplate and the gray bezel and gently pry apart 3 Position the thermostat over the junction box and secure it using the two suppli...

Страница 3: ...cycle or hold an inconsistent temperature 1 Press and at the same time to enter the setup 2 Press M 3 times or will flash 3 Press or to select the option suitable for your heater Select for fan forced heaters or for convection heaters including baseboard heaters 4 The display will blink for 6 seconds before returning to the main screen Time and Day Set the current time and format 1 Press and at th...

Страница 4: ...ates that a temporary hold has been set The next scheduled event will override this temperature change Lock Function Use the lock function to prevent the settings from being changed inadvertently 1 Press and at the same time 2 Press M 5 times The icon will blink 3 Press or to toggle it on and off The icon blinks fast to indicate that it is enabled and blinks slow to indicate that it is disabled 4 ...

Страница 5: ...to conserve energy while you are away for long periods of time Comfort This mode is used to slightly increase the temperature across all programmed events to maintain a more comfortable temperature Economy This mode is used to slightly decrease the temperature across all programmed events to save energy To enable disable a quick mode 1 Press and hold M for 3 seconds All of the quick mode icons wil...

Отзывы: