TOOLS REQUIRED
Tape Measure
Straight
and Phillips
Screwdrivers
Drill and Drill Bits
Stud Finder
®
®
®
®
®
Level
INSTALLATION INSTRUCTIONS
3
GROUNDING INSTRUCTIONS
WARNING
: To reduce the risk of fire,
do not store or use gasoline or other
flammable vapors or liquids in the
vicinity of the heater.
CAUTION
: High temperature, risk of
fire, keep electrical cords, drapery,
furnishings, and other combustibles
at least 3 feet (0.9 m) from the front
of the heater.
This heater is for use on 240 Volts.
The cord has a plug as shown on
Figure 1. No adapter should be
used with this unit. The type outlet
is a 240 Volt grounding outlet.
When properly installed, it provides
a ground connection through the
cord to the heater to protect the
operator from electric shock.
Receptacle Configuration
NEMA #6-20R
Figure 1
HEATER LOCATION AND CLEARANCES
The heater is intended for flat use on a hard
floor, table top, desk or on shelf, and the like,
or suspended on a wall or ceiling by means of
provided hanger bracket.
When suspended from wall or ceiling, heater
should be located along outside walls to
provide perimeter air circulation.
The discharge air should wipe the walls
without blowing directly on them (Figure 2).
If heater is to be tilted on horizontal axis after
mounting - ensure a minimum clearance of
26.5 in. (67 cm) between floor and bottom
of heater. Also, when mounted to ceiling,
ensure a minimum clearance of 3.5 in. (9 cm)
from ceiling to top of heater. Ensure the air
discharge is parallel to or away from walls.
Outside Wall
Discharge
Figure 2
Plug Configuration
NEMA #6-20P