Resetting the Manual Reset Limit Control

Warranty

  How to operate your heater

The room temperature is controlled by a line voltage thermostat 

located either on the wall or built-in to the heater.
1. Once installation is complete and power has been restored, 

turn the thermostat knob fully clockwise.
2. When the room reaches your comfort level, turn the thermo-

stat knob counterclockwise until the heater turns off. The heater 

will automatically cycle around this preset temperature.
3. To reduce the room temperature, turn the knob counterclock-

wise. To increase the room temperature, turn the knob clockwise.

 About the Manual Reset Temperature Limit Control

The heater is protected by a temperature-limiting control. The 

manual reset temperature limit control is designed to open the 

heater circuit when excessive operating temperatures are detect-

ed. The problem must be assessed and the limit must be reset to 

resume operation.

For more effective and safer operation and to prolong the life of 

the heater, read the Owner’s Guide and follow the instructions. 

Failure to properly maintain the heater will void any warranty and 

may cause the heater to function improperly. 

LIMITED THREE YEAR WARRANTY: Cadet will repair or replace 

any Com-Pak Max (CM) heater found to be defective within three 

years after the date of purchase.

These warranties do not apply:

1. Damage occurs to the product through improper installation or 

incorrect supply voltage;

2. Damage occurs to the product through improper maintenance, 

misuse, abuse, accident, or alteration;

3. The use of unauthorized accessories or unauthorized com-

ponents constitutes an alteration and voids all warranties. Refer 

to Cadet website or call customer service at 855.223.3887 or 

360.693.2505 for list of authorized accessories and components. 

4. Cadet’s warranty is limited to repair or replacement.

5. In the event Cadet elects to replace any part of your Cadet 

product, the replacement parts are subject to the same warran-

ties as the product. The installation of replacement parts does 

not modify or extend the underlying warranties. Replacement 

or repair of any Cadet product or part does not create any new 

warranties.

If you believe your Cadet product is defective, please contact 

Cadet during the warranty period, for instructions on how to have 

the repair or replacement processed.

Parts and Service

Visit 

cadetheat.com/parts-service

 for information on where to 

obtain parts and service.

Reduce-Reuse-Recycle

This product is made primarily of recyclable materials. 

You can reduce your carbon footprint by recycling this 

product at the end of its useful life. Contact your local 

recycling support center for further recycling instruc-

tions.

1. Make sure all wires are properly connected 

and installation is complete before you turn on 

the heater.

2. Do not operate without grill.

3. Do not tamper with the high-temperature safety 

shutoff.

Resetting the Manual Reset Temperature Limit Control

If the manual reset limit control has opened the heater circuit due to excessive operating 

temperatures, the heater will not work until the manual reset limit button is pressed. 
After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit 

to trip (typically the heater is blocked or needs cleaning-see Maintenance Instructions);  use a 

narrow object such as a ball-point pen to access the manual reset button through the upper-

left center section of the heater grill. Press FIRMLY and be sure to listen and feel for a click, 

indicating it has been reset.

Complete installation

 

After installation, turn your heater to the highest setting and let it run for 30 minutes. Some smoking may occur as the element initially burns off residue 

from manufacturing.
If your heater shows signs of overheating, such as glowing red or repeatedly getting unusually hot and shutting off, immediately turn off the circuit breaker 

and call us.
If the high-temperature safety shutoff trips more than once a day, replace the heater.

Page 5

     

Manual 

Reset 

Limit 

Button

Отзывы: