Verify power has been turned off before starting any work! 

•  The Com-Pak Max can only be mounted with the element up or to the left. It cannot be mounted in 

the ceiling or in the floor. For multiple heater wiring, see page 6.

•  For cleaner performance and longer heater life, install your heater 12 inches (30.5 cm) from the 

floor.

•  All models can be installed to be Americans with Disabilities Act (ADA) compliant. Check your state 

and local requirements.

•  The wall can label arrows show the correct mounting orientation (arrows must point up).
• 

A wall thermostat is required for ALL models without a built-in thermostat (CM152, CM158, CM192, 

CM198) and horizontally mounted units must use a wall thermostat. A Cadet electronic thermostat 

is recommended for ultimate control and comfort.

If you haven’t installed drywall yet, make sure the front of the wall can extends beyond the front edge of 

the wall stud to match the drywall depth (See Figure 3). 

If you already have drywall installed, place the can into the cutout so the front is flush with the drywall. 

Fasten the wall can to the stud with two screws through holes provided in the wall can (See Figure 3). 

As an option, the foam pad provided may be attached to the side of the wall can to square the wall can 

to the stud.

STEP 3

 

Mount the wall can

STEP 1

 

Cut a hole in the wall next to a wall stud

attach foam pad here

STEP 2

 

Locate or route electrical supply wires

Route the electrical supply wire from the circuit breaker to the heater location.
Remove a knockout from the wall can (best location is closest to heater wires) and attach the supply 

wire with a cable clamp connector (not included) leaving a minimum of 6 inches (15.2 cm) wire lead 

(See Figure 3). 

INSTALLATION INSTRUCTIONS

Figure 3 

View from top of wall can

If you haven’t installed drywall yet, skip this step.

TIPS BEFORE YOU BEGIN

Figure 2

front of wall can extends beyond front 

edge of wall stud to match drywall depth

drywall

wall 

stud

twist with screwdriver 

to remove one of the 

knockouts

attach supply wire 

with a cable clamp 

connector

fasten with 2 

wood screws

4

Figure 1

Vertical - Element at top

Horizontal - Element at left

Содержание COM-PAK MAX CM192

Страница 1: ...max For how to videos or more information please visit Thank you for your purchase Question or problem Let us solve it with a single phone call email or online chat We ll save you a trip back to the s...

Страница 2: ...c shock or injury to persons 11 The heater must be installed in a fixed permanent location When using electrical appliances basic precautions should always be followed to reduce the risk of fire elect...

Страница 3: ...t least 2 feet 61 cm away to prevent contact with water 4 Heater must be installed in a wall can Model CM wall can model CC or CCSM 5 DO NOT install the heater in a floor in the ceiling below a towel...

Страница 4: ...alled place the can into the cutout so the front is flush with the drywall Fasten the wall can to the stud with two screws through holes provided in the wall can See Figure 3 As an option the foam pad...

Страница 5: ...r or wrap with electrical tape Move Yellow Connector from Terminal A to Terminal B Disconnect and cut wire with Blue Connector at Terminal B Cap loose end with wire connector or wrap with electrical t...

Страница 6: ...ical supply wire and cable clamp connectors are required The heaters must be in the same room Maximum amperage you can put on one circuit breaker is limited to 80 of the circuit breaker capacity this...

Страница 7: ...ur thermostat to the highest setting and let the heater run for 30 minutes Some smoking may occur as the element initially burns off residue from manufacturing If your heater shows signs of overheatin...

Страница 8: ...ore than once a day replace the heater 3 Adjust grill so louvers do not press against reset button 4 Call a licensed electrician 5 Turn off power at main disconnect panel Inspect and or tighten all th...

Отзывы: