background image

IMPORTANT INFORMATION

SAVE THESE INSTRUCTIONS

WARNING!

When working with electricity, turn
the electrical power off at the elec-
trical panel board and lock or tag
the circuit breaker door. Failure to
do so could result in serious electri-
cal shock, burns, or possible death.

1. Read all instructions before using this heater.

2. This heater is hot when in use. To avoid burns, do not let bare

skin touch hot surfaces.  Keep combustible materials, such
as furniture, pillows, bedding, papers, clothes, and curtains
at least 12 inches from the front of the heater and 6 inches
on each side and rear. Heaters must be kept clean of lint, dirt
and debris. (See Maintenance Instructions)

3. Extreme caution is necessary when any heater is used by or

near children or invalids.

4. Do not insert or allow foreign objects to enter any ventila-

tion or exhaust opening as this may cause an electric
shock or fire, or damage the heater.

5. To prevent a possible fire, do not block air intakes or

exhaust in any manner. 

6. A heater has hot and arcing or sparking parts inside. Do not

place heater in any area where combustible vapors, gases,
liquids, or excessive lint or dust are present.

7. Use this heater only as described in this manual. Any other

use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.

TEL: 360-693-2505  Fax: 360-694-6939  P.O. Box 1675  Vancouver, WA  98668-1675

Tools Required:
Appropriate Fasteners 
Crescent Wrench 
Phillips Screwdriver

Straight Screwdriver 
Strain Relief Connector
Wire Strippers

OWNER’S GUIDE

The Unit Heater

Models: 
CEH-003M
CEH-003MB
CEH-003P
CEH-003PB

CEH-003R
CEH-003SB
CEH-005M
CEH-005MB

CEH-005P
CEH-005PB
CEH-005R
CEH-005SB

• Commercial grade high temperature 

manual reset with 25 amp rating at 
240 volt

• High mass, tubular element for longer life

• Fan delay eliminates cold draft on startup and 

disperses residual heat on shutdown

• Rugged die formed construction for durability

• Wire single or three phase to suit the application

• Mounts vertically or horizontally

• 5 Year Warranty

Features & Benefits

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CEH-003M

Страница 1: ...t a possible fire do not block air intakes or exhaust in any manner 6 A heater has hot and arcing or sparking parts inside Do not place heater in any area where combustible vapors gases liquids or exc...

Страница 2: ...ase follow these recommendations to avoid potential problems with the function and safety of the heater Mounting the CEH Unit Heater CAUTION THE CEILING OR WALL MOUNTING STRUCTURE AND ANCHORING PROVIS...

Страница 3: ...of adequate strength to support the heater Plaster or suspended ceilings will not support this type of heater For greater stability we recommend the use of threaded rods Do not mount the heater where...

Страница 4: ...tactor terminal and b Disconnect the red wire from the junction block and connect it to the terminal in the center of the block CAUTION TO AVOID ELECTRICAL SHOCK BE SURE ELECTRICITY IS TURNED OFF AT E...

Страница 5: ...l models The limit is located on the front of the heater The manual reset limit will not reset until the button is pushed 208 240V line voltage control heaters use two manual reset limits FRONT BACK F...

Страница 6: ...it wiring must be NEC Class 1 600 Volt Copper Conductor and 90 C Insulation NOTE DENOTES OPTIONAL EQUIPMENT May not be used with built in thermostat THERMOSTAT Factory installed option only in Canada...

Страница 7: ...CEK TB2 TWO STAGE INTEGRAL THERMOSTAT OPTIONAL 7 IMPORTANT When ordering replacement parts specify the heater Model Number Serial Number and Product Date Code shown on unit rating plate or label found...

Страница 8: ...See Operation and Maintenance section for instructions 4 Location elevation exceeds recommended 7500 feet 5 Power to heater needs to be constant all the time Symptom Problem Solution Troubleshooting C...