11  SAFETY DEVICES AND ALARMS

11.1  SAFETY DEVICES

The product is supplied with the following safety devices

11.2  PRESSURE SWITCH

•  It controls pressure in the fume duct. It blocks the pellet feed screw in the following instances:

•  - clogged exhaust

•  - Significant negative (wind)

•  - clogged fume passages

•  - open pellet loading tank

•  - open fire door or worn/broken gaskets.

11.3  SMOKE TEMPERATURE PROBE

Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the 

preset value.

11.4  CONTACT THERMOSTAT IN THE FUEL HOPPER

If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.

11.5  ELECTRICAL SAFETY

The product is protected against sudden current surges by a main fuse in the power supply panel on the rear part of the product. 

Other fuses that protect the electronic boards are found on the latter.

11.6  SMOKE FAN

If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.

11.7  GEAR MOTOR

If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of 

cooling is reached.

11.8  TEMPORARY POWER CUT

If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a cooling/restart 

cycle.

11.9  FAILED START-UP

If during ignition no flame develops, the boiler will go into alarm condition.

11.10  BLACKOUT WITH THE BOILER ON

In the event of a power cut (

blAc-out

) the boiler behaves as follows:

•  Blackout below 10”: it returns to its operation in progress;

•  In the event of a power cut that lasts over 10” with the boiler on or in the start-up stage, when the boiler is powered again it 

goes back to the previous operating condition with the following procedure:

1)  It performs a cooling phase to the maximum.
2)  Performs a new ignition.

During stage 1 the panel displays ON BLACK OUT.

During stage 2 the panel displays Start-up.

If during stage 1 the boiler receives commands from the panel and thus carried out manually by the user, then the boiler stops 

executing the blackout recovery status and proceeds to restart or shutdown as requested by the command.

11.11  ALARM ALERTS

Whenever an operating condition other than that designed for the regular operation of the boiler occurs, there is an alarm condi-

tion.

The control panel gives information on the reason of the alarm in progress.

Содержание TILE3 MOON

Страница 1: ...EN 2019CADELsrl Allrightsreserved Tuttiidirittiriservati USER MANUAL Pellet Stove WALL3 PLUS TILE3 PLUS MOON LEAN3 PLUS...

Страница 2: ...T FICHA DO PRODUTO PL KARTA PRODUKTU CZ INFORMA N LIST V ROBKU SK INFORMA N LIST V ROBKU RO FI A PRODUSULUI HU TERM KISMERTET ADATLAP SL PODATKOVNI LIST IZDELKA HR INFORMACIJSKI LIST PROIZVODA GR BG L...

Страница 3: ...erg tique Energie effici ntieklasse Energieeffizienzklasse Clase de eficiencia energ tica Classe de Efici ncia Energ tica Klasa efektywno ci energetycznej T da energetick innosti Trieda energetickej i...

Страница 4: ...inkovitosti Indeks energetske u inkovitosti Energijos efektyvumo indeksas Energiat hususe indeks Indeks energieffektivitet Energieffektivitetsindex 128 128 128 128 Efficienza utile alla potenza termic...

Страница 5: ...ntenimiento peri dico indicadas en los cap tulos espec ficos del manual de instrucciones Respeitar as advert ncias e as indica es de instala o e manuten o peri dica apresentadas nos cap tulos espec fi...

Страница 6: ...PAG 10 16 9 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 10 17 9 19 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION K SETTINGS MENU A PAG 10 17 9 20 COMFORT MODE FUNCTI...

Страница 7: ...ive 2009 125 EC Eco Design and where applicable Directives 2014 35 EU LowVoltage 2014 30 EU Electromagnetic Compatibility 2014 53 EU Radio Frequency 2011 65 EU ROhS Read carefully the instruction cont...

Страница 8: ...ith 1 meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during...

Страница 9: ...ranty to be valid and effective We recommend testing the product before completion with the relative finishes claddings painting of walls etc Installations not meeting the current standards improper u...

Страница 10: ...acoustic pollution The company declines all liability for any damage which may be caused directly or indirectly to persons animals or objects as a consequence of non compliance with any prescription...

Страница 11: ...provided by national laws transposing the Directive 2012 19 EU Separate waste collection and recycling of unused electric and electronic equipment batteries and accumulators helps to save natural reso...

Страница 12: ...onwload wi fi http www free point it it downloads https www pegasoheating com it documenti 9 USE 9 1 INTRODUCTION To have the best performance with the lowest consumption please follow the here descri...

Страница 13: ...e display is secured by a screw To allow the display to rotate 90 remove the screw see Fig 6 and Fig 7 Fig 6 Removethescrew Fig 7 Rotatethedisplay 9 3 CONTROL PANEL DISPLAY Menu items Fig 8 Display Fi...

Страница 14: ...rew Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes h Pellet Recipe i Smoke Fan rpm j ComponentsTest dis...

Страница 15: ...tton Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit g OffT...

Страница 16: ...to confirm Scroll to Technical Menu using the arrows Press menu to confirm Select ProductType Service Status Memory Parameters with the keys Press menu to confirm and esc to exit 9 6 INFO MENU Product...

Страница 17: ...l shutdown phase which entails the automatic execution of the following stages Pellet loading is stopped The room fan continues to operate until the requested temperature is reached The flue fan is se...

Страница 18: ...to maximum heat output 5 and the fans to minimum output 1 this may cause overheating andthe THERMALSAFETY alarmtogooff Comfort Mode this function allows activating deactivating the fans at power 1 Fi...

Страница 19: ...rogramme will not appear active in the status screen Continue to program the following days or press ESC to exit Repeat the procedure to program the other timers 9 13 PROGRAMMING EXAMPLES P1 P2 on off...

Страница 20: ...C or external thermostat with closed contact for at least 20 to avoid false recalls After 5 minutes from the beginning of the switch off procedure 9 16 SLEEP FUNCTION MAIN MENU The sleep function is...

Страница 21: ...ank door is opened LOAD TIME OUT the control unit is equipped with a timer that acoustically warns with 3 beeps that the load time available is over If the user requires more time to finish loading th...

Страница 22: ...A05 depression alarm and proceeds to switch off Wait until it switches off then light it again Fig 23 Dooropen Fig 24 deterioratedgasket Fig 25 Timer 90seconds Tooperatecorrectly thestovemustworkwitht...

Страница 23: ...temperature 0 C 50 C 38 khz infrared signal Used batteries contain metals which are harmful for the environment they must therefore be disposed of separately in the special containers Fig 27 Remoteco...

Страница 24: ...e flame goes out due to lack of fuel and until a minimum level of cooling is reached 11 8 TEMPORARY POWER CUT If the power cut lasts less than 10 the boiler returns to its previous operating status if...

Страница 25: ...side fire ducts cleaning clogged hose connection excess flue length unfavou rable weather conditions and clogged stove A08 Abnormal smoke fan operation If the alarm persists contact the service centr...

Страница 26: ...and Fig 29 from its seat and empty it from the ash If becessary clean with a pointed object the holes obstructed by encrustations see Fig 30 Fig 31 Ashtrayboxcleaning Fig 32 Burningpotboxcleaning Fig...

Страница 27: ...6 Inspectionpanelremoving Unscrew the 2 screws from the galvanised panel see Fig 35 Remove the inspection panel see Fig 36 Fig 37 Cleaningwithabrush Fig 38 Fumechambercleaning Clean the 2 internal fum...

Страница 28: ...ably damage the varnish 12 8 CLEANING OF CERAMIC AND STONE PANELS Somestovemodelshasanexternalliningmadeupofceramicorstone Thesepiecesarehandmadethereforetheycouldinevitably present crazings seediness...

Страница 29: ...ASE OF ANOMALY 13 1 PROBLEM SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Inc...

Страница 30: ...Auger blocked by a foreign object for example nails Clean the auger The auger geared motor is out of order Replace the geared motor Check if on the display there is an ACTIVE ALARM Have the stove che...

Страница 31: ...ulty fume tem perature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume pip...

Страница 32: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2021...

Отзывы: