new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
34
LEGEND
2
Electronic board
3
Storage tank
4
Room thermostat
5
Storage tank thermostat
6
Switch box
7
Strap-on thermostat
8
Booster Pump
9
Non-return valve
10
Expansion vessel
11
Hot H2O manifold
12
Cold H2O manifold
13
Radiator
14
Auxiliary boiler
15
Zone valve
A
Boiler power supply
B
Auxiliary system pump supply
C
Alarm signal
8.16 OPERATING MODE
The operating mode for hydro boilers is AUTOMATIC only (manual mode is not envisioned). Flame modulation is managed accor-
ding to the “System configuration” of the room probe placed on the rear of the appliance (see drawing), by the external thermo-
stat, by the boiler water temperature or by the NTC probes.
Fig. 71 - Probe position
8.17 ELECTRICAL CONNECTIONS
Terminal board contacts (see ):
CONTACTS
POS.1-2 EXTERNAL THERMOSTAT/PUFFER THERMOSTAT
POS.3-4 PUFFER/BOILER PROBE
POS.5 EARTHING
POS.6-7 ADDITIONAL BOILER
POS.8 3-WAY VALVE NEUTRAL
POS.9 3-WAY VALVE PHASE (DHW)
POS.10 3-WAY VALVE PHASE (heating)
To access the “W” terminal board, remove the cap as shown in part 1 of the manual (in the paragraph dedicated to removing
the back), then loosen the two “z” screws and remove the “W” terminal board. Make the necessary connections and reassemble
everything.