На нашем сайте вы можете бесплатно скачать инструкцию пользователя для установщика Cadel PRINCE 11. Это незаменимый ресурс, чтобы правильно настроить и использовать данное оборудование. Загрузите его прямо сейчас с нашего сайта manualshive.com.
EN
USER MANUAL
Pellet Stove
PRINCE 11 - KOBE 11 - FENICE 11
PRINCE PLUS 11 - KOBE PLUS 11 - FENICE PLUS 11
SPARK 11- INDACO 11
Original Instructions | ©2022 CADEL srl | All rights reserved - Tutti i diritti riservati
new
Страница 1: ...EN USER MANUAL Pellet Stove PRINCE 11 KOBE 11 FENICE 11 PRINCE PLUS 11 KOBE PLUS 11 FENICE PLUS 11 SPARK 11 INDACO 11 OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new...
Страница 2: ...16 EASYSETFEATURE SEESECTIONXSETTINGSMENU A PAG 14 20 8 17 PELLETS RECIPE SEE SECTION H SETTINGS MENU A PAG 14 21 8 18 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 14 22 8 19 CHIMNEY SWEEP FU...
Страница 3: ...lost you can request another copy from the localTechnical Dept or download it directly from the company s website Alllocalregulations includingthosereferringtonationalandEuropeanstandards mustbeobserv...
Страница 4: ...the interval between routine maintenance operations according to the operating condition of the product We furthermore point out that these operating conditions increase the risk of premature wear of...
Страница 5: ...meter If the floor is made of combustible material we recommend using a protector made of in combustiblematerial steel glass etc thatalsoprotectsthefrontpartfromanyfallingburnt particles during cleani...
Страница 6: ...ntheproductisswitchedonforthefirsttime itisnormalforittoemitsmokeduetothepaintheatingupforthefirsttime Therefore make sure the room it is installed in is well ventilated Periodically check and empty t...
Страница 7: ...ault the customer must have the guarantee certificate and present it with the proof of purchase document to theTechnical Assistance Office Theguaranteedoesnotcovermalfunctionsand ordamagetotheapplianc...
Страница 8: ...rvices 6 DISPOSAL OF MATERIALS 6 1 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compl...
Страница 9: ...TORS Fig 2 Wastedisposal Thissymbol whichisusedontheproduct batteries accumulatorsoronthepackagingordocuments meansthatattheendofits useful life this product the batteries and the accumulators include...
Страница 10: ...he com petent body APPLIANCE BAG BAG OF ACCESSORIES BUBBLEWRAP PROTECTIVE SHEET LABELS POLYETHYLENE LD PE 04 SORTED waste collection PLASTIC Check the instructions of the com petent body POLYSTYRENE F...
Страница 11: ...US ProcedureifonlyvalidformodelswithEASYCONNECTPLUSWi Fitechnology Fig 3 EASYCONNECTPLUSmodule Fig 4 EASYCONNECTPLUSdisplay Fig 5 EASYCONNECTPLUSapp The documentation for connecting theWi Fi and using...
Страница 12: ...roperty or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation N B forstoveswitha3 buttondisplay theprogrammab...
Страница 13: ...tee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxioustopeopleandanimals Set values from 1 to 5 are de...
Страница 14: ...Loading displayed only when the boiler is switched off d Tone e Ext Thermostat activation f Auto Eco activation g OffTime Eco default 5 minutes x Easy Set h Pellet Recipe i Smoke Fan rpm j ComponentsT...
Страница 15: ...Scroll to Settings using the arrows Press menu to confirm Scroll to Auto Eco activation using the arrows Press menu to confirm Select On with the keys Press menu to confirm and esc to exit g OffTime...
Страница 16: ...ng the arrows Press menu to confirm Scroll to the Chimney Sweep Function function using the arrows Press menu to confirm Select On with the keys Off by default Press menu to confirm and esc to exit l...
Страница 17: ...blackens and the burningpottobecomeencrusted cleanthestove cleanthefumeconduitandthechimneyflue ATTENTION Makesurepelletsandashhavenotaccumulatedinthebrazierduetofailedignition Ifthebrazierisnotclea...
Страница 18: ...6 Fig 14 Display Fig 15 Display Fig 16 Display Withfunction 1 or 2 or 3 or 4 or 5 thefanisforcedtoworkattheselectedoutput Forexample bysetting 3 evenifthe fan is set to heat output 5 it will work as i...
Страница 19: ...or keyhighlightwiththewhitebackgroundthedayinwhichonewishestoactivatethetimerandconfirmwiththe menu key Ifno day of the week is confirmed as active in turn the timer programme will not appear active...
Страница 20: ...procedure begins the panel shows Off Active Eco small flashing flame see Fig 21 When the stove is switched off the panel shows active OFF ECO with the flame icon off For an ECO switch on the following...
Страница 21: ...madewiththesupportoftheauthorisedtechnician ActivatesonlywiththeEasySetfunctiondisabled SET 0 Thisfunctionisforadaptingthestovetothepelletsthatarebeingused Infact asthereareseveraltypesofpelletsonthem...
Страница 22: ...causeabadcombustion afrequentburningpotobstructionandexhaustconduitsobstruction Furtherit decreases the calorific value soils the glass and increases consumptions and ash and unburnt granules quantity...
Страница 23: ...pression alarm and proceeds to switch off Wait until it switches off then light it again Fig 26 Dooropen Fig 27 deterioratedgasket Fig 28 Timer 90seconds Tooperatecorrectly thestovemustworkwiththepell...
Страница 24: ...mperature 0 C 50 C 38 khz infrared signal Used batteries contain metals which are harmful for the environment they must therefore be disposed of separately in the special containers Fig 30 Remotecontr...
Страница 25: ...run until the flame goes out due to lack of fuel and until a minimum level of cooling is reached 12 7 TEMPORARY POWER CUT If the power cut lasts less than 10 the boiler returns to its previous operati...
Страница 26: ...utine maintenance alert it does not block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centr...
Страница 27: ...UPANDOPTI MALOPERATIONOFYOURPELLETPRODUCT For the brazier to be cleaned properly remove it from its housing completely and thoroughly clean all the holes and the grate on the bottom If good quality p...
Страница 28: ...they must be removed with the aid of a vacuum cleaner see Fig 37 13 5 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove re...
Страница 29: ...orTechnicalAssistanceCentre during thenecessaryannualendofseasonscheduledmaintenanceoperations Thiswaythepaintwillprotecttheinnerpartsofthecom bustion chamber blocking any type of oxidative process Fi...
Страница 30: ...M SOLVING Before of every Authorized Technician intervention the same Technician has the duty to check if the parame tersofthemotherboardcorrespondtothoseofthetableyouown Incaseofdoubtsregardingtheuse...
Страница 31: ...t loading Check if on the display there is an ACTIVE ALARM Have the stove checked Flames are weak and orange coloured pellets do not burn properly and the glass blackens Not sufficient com bustion air...
Страница 32: ...elisation can be noxious to health The stove is at its highest power but does not heat up Ambient temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove...
Страница 33: ...Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 90 Useful efficiency at min...
Страница 34: ...0 mg Nm3 NOx al 13 O2 130 mg Nm3 Heat output Nominal heat output Pnom 10 5 kW Minimum heat output indicative Pmin 3 kW Useful efficiency NCV as received Useful efficiency at nominal heat output th nom...
Страница 35: ...35 KOBE FENICE SPARK INDACO PRINCE...
Страница 36: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...