KRISS
3
- TECNA
3
- EVO
3
- ELISE
3
- SHELL
3
- CRISTAL
3
- GLASS - VERVE AT - PRETTY AT - TITANIA AT - VENERE AT - BREEZE AT
32
Fig. 75 - Casing removal
Fig. 76 - Digital pressure switch connection
DATA
P1
P2
P3
P4
P5
Stove depression -
temperature 7 kW 19/21 Pa - 110°C
32/35 Pa - 125°C
48/50 Pa - 145°C
52/54 Pa - 160°C
63/65 Pa - 165°C
Stove depression
- temperature 8.5
kW
19/21 Pa - 110°C
32/35 Pa - 125°C
49/51 Pa - 155°C
63/65 Pa - 165°C
68/70 Pa - 180°C
Stove depression -
temperature 9 kW 19/21 Pa - 110°C
32/35 Pa - 125°C
49/51 Pa - 155°C
63/65 Pa - 165°C
73/75 Pa - 190°C
NB: for good combustion, the depression values must be b -5 Pa and the temperature values b - 10°C.
6
SPECIAL MAINTENANCE
6.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
6.2
FEED SCREW MAINTENANCE
Proceed as follows for the feed screw maintenance:
Содержание BREEZE AIRTIGHT
Страница 46: ...NOTE ...