Cadac CDC five_02-01-2020_Rev-7.docx
Page. 63 / 78
GEQ
All output busses feature 4-band fully parametric EQ, variable HPF and LPF plus a 1/3 octave GEQ.
By pressing the GEQ [17] button - to the left of the screen - when the busses are selected, the GEQ
screen will open. This shows 31 bands in BYPASS mode (press BYPASS to take it out of bypass) on
the screen.
The GEQ is split into active bands highlighted by the blue box which can be cut or boosted by the
faders. The bands outside the blue box are inactive. The faders are now mapped to the active bands
(16 bands will be active) with the frequencies shown both on the screen and the OLEDs above the
faders. Pressing the SELECT button under the BUS will activate the GEQ for that individual BUS. Once
a fader is moved, the ON light will illuminate blue and the applied boost or cut will displayed on the
GEQ screen. By pressing the ON button, the boost or cut will be zeroed for that GEQ band.
43: With the GEQ open on the outputs, the faders will be mapped to the relevant frequency
The active
area of the
GEQ can be
changed by
moving the
highlighted
blue area.
16 bands are
always
visible.
By cutting or
boosting the
band using
the fader, the
ON button will
light blue
indicating the
band has a
cut or boost
The EQ
bands map to
the faders for
adjustment -
highlighted by
the white
arrows
The SEL
button selects
the BUS that
the GEQ is
active on