background image

CUSTOMER RELEASE NOTES

2/7/00 P/N: 9032741-08

Subject to Change Without Notice

 Page 5 of 7

F0615-E

35 Industrial Way
PO Box 5005
Rochester, NH 03867-5005
(603)332-9400

17. If Hewlett-Packard GBIC (Gigabit Ethernet Interface Converter) modules are inserted/removed on the

ELS100-24TXG while power is applied to the switch, they may become damaged. The damage results
in the presence and type identity of the GBIC not being recognized by software. Data will still be
switched successfully through the port.

18. The following issues are present when using the Port Trunking feature in this release of firmware:

  When configuring Port Trunking, the Spanning Tree path costs on ports can become

misconfigured.

  Ports in different VLANs can be placed into the same trunk, which should not be allowed.

  Trying to add a port to a trunk that has been created in a different switch cluster (group of 8 ports)

causes the ports in the trunk to be erroneously deleted.

  When a trunk group is configured, and the first port of that trunk group becomes disabled, local

management reports that the entire trunk status is disabled; this is a false signal. The status can
be corrected by disabling and re-enabling that port.

  This release does not provide compatibility with DEC Hunt Group proprietary protocol mode of

operation; this functionality will be provided in a future release.

Please refer to the addendum to the ELS100-24TXG/TXM User Guides (Document # 9033194) for
detailed information regarding port trunking configuration.

19. When a BootP server and DHCP server are both present in the network, in some cases only the IP

address will be acquired; the firmware image will not be received. Both protocols work properly when
only one server type is present. This condition also existed in earlier versions of firmware.  Cabletron’s
recommendation is to remove the DHCP server and reboot the switch; this will cause the switch to send
BootP requests and receive an image from the BootP server.

20. When Microsoft Internet Explorer is used to access Cabletron WebView management, the initial start-

up time is excessive (approximately 20 minutes), after which it performs normally. To avoid this delay,
the switch’s IP address should be added to Internet Explorer’s Proxies “Ignore” area.

21. When using Cabletron WebView, an ELS100-24TXM which does not have an uplink installed is

incorrectly reported to be an ELS100-24TX.  This condition also existed in earlier versions of firmware.

22. Older versions of ELS100-24TX may not support the Cabletron WebView image download, due to

insufficient memory.

23. When configuring 802.1Q trunks, the VLAN that contains the ports configured as trunks must not have

those ports on the egress list for that VLAN. This results in a mis-configuration.

24. When configuring Port Trunks as 802.1Q trunks, you must add the port trunks to the egress list as a

pair. Adding them separately results in an error reporting a VLAN violation.

25. When performing a TFTP file download to the switch, it may be necessary to repeat the process to

successfully receive the entire file. Also, if a file that has been received is corrupt, the switch may enter
a state where it is expecting to receive a new image via XMODEM download. This can be verified and
corrected by invoking a local management session to the console (serial) port; the switch will send the
character “c” to the console station until an XMODEM transfer of a new firmware image file is sent.  For
additional information, please reference 

http://www.cabletron.com/support/techtips/tk0564-9.html

for XMODEM instructions, and 

http://www.cabletron.com/support/techtips/tk0490-9.html

  

for

TFTP/BootP instructions.

26. Contrary to the user manuals, the READ/WRITE and READ-ONLY passwords are case-sensitive in this

version of firmware.  The passwords must be typed exactly as they were created.

27. (Added 2/7/2000): The READ ONLY password is not saved to non-volatile memory. It will become

effective and active when created, but will not be saved when the device is reset. Resetting the device
clears the READ ONLY password. Also, when the READ/WRITE password is modified and saved, this
will clear the READ ONLY password, allowing READ access with just a carriage return at the Login:
prompt. These problems will be resolved in the next firmware release.

Any other problems than those listed above should be reported to our Technical Support Staff.

Содержание SmartSTACK ELS100-24TXG

Страница 1: ...100 Mbps RJ45 ports and 2 100BASE FX multimode and or singlemode fiber SC ports via a plug in module EPIM100 2F2 2F3 2F4 RJ45 ports 1 and 2 are disabled when the fiber ports are installed for a total of 24 potentially active ports It is recommended that one thoroughly review this release note prior to the installation or upgrade of this product FIRMWARE SPECIFICATION Status Version No Version Disp...

Страница 2: ...fic Management Dynamic Multicast Filtering YES 802 1Q VLAN tagging and identification YES 802 1D Transparent Bridging YES Auto Negotiation YES Broadcast Suppression YES Local Management via TELNET YES Modem Support external YES Port Mirroring YES RMON YES SNMP YES Virtual Networking VLANs YES Cabletron WebView YES Port Trunking Link Aggregation YES INSTALLATION AND CONFIGURATION NOTES In general t...

Страница 3: ...ed here as a supplement to Table 5 2 in the Installation and User Guide Variable Description SwitchSpanningTreeStandby Globally enable disable Spanning Tree Standby on the switch 6 A change has been made which will prevent a mis configuration of Port Mirroring Port mirroring mis configuration causes the feature to be enabled in the hardware although the configuration screen indicates it is disable...

Страница 4: ... VLANs that can be configured on the switch is eight ELS100 24TXG 24TXM The maximum number of port based VLANs that can be configured on switches manufactured in week 9908 and later and running this version of firmware is 128 Any VLAN ID within the range of 0 4095 is valid but only 128 VLANs can be created on the switch at one time Note Units manufactured prior to week 9908 will support only eight...

Страница 5: ...ssive approximately 20 minutes after which it performs normally To avoid this delay the switch s IP address should be added to Internet Explorer s Proxies Ignore area 21 When using Cabletron WebView an ELS100 24TXM which does not have an uplink installed is incorrectly reported to be an ELS100 24TX This condition also existed in earlier versions of firmware 22 Older versions of ELS100 24TX may not...

Страница 6: ...02 3 clause 14 IEEE 802 3u 100Base TX ISO IEC 8802 3 clause 25 IEEE 802 3u 100Base FX IEEE 802 3x Flow Control IETF STANDARDS MIB SUPPORT RFC No Title Groups Supported 1213 MIB II System Interfaces Address Translation IP ICMP TCP UDP Transmission and SNMP 1398 Ethernet MIB Ethernet specific statistics subgroup of the MIB II Transmission Group 1493 Bridge MIB Spanning Tree Forwarding Table Informat...

Страница 7: ...terpriseSpecific 6 RFC 1493 IETF Bridge ENTERPRISE dot1dBridge 1 3 6 1 2 1 17 newRoot specific 1 topologyChange 2 RFC 1757 IETF RMON ENTERPRISE rmon 1 3 6 1 2 1 16 risingAlarm 1 fallingAlarm 2 CABLETRON PRIVATE ENTERPRISE TRAP SUPPORT Title None Please reference SNMP TRAP SUPPORT Section above GLOBAL SUPPORT By Phone 603 332 9400 By Email support cabletron com By Web http www cabletron com support...