Страница 3: ...AMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HA...

Страница 4: ...in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible fo...

Страница 5: ...Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above di...

Страница 6: ...maintenance checks or adjustments The output is factory set and does not allow any user adjustment Class 1 Laser transceivers comply with the following safety standards 21 CFR 1040 10 and 1040 11 U S...

Страница 7: ...nents 2 4 Setting the Module Card DIP Switch 2 5 Chapter 3 Operation Flexible Network Bus FNB 3 1 System Management Buses 3 2 SMB 1 Bus 3 2 SMB 10 Bus 3 2 System Diagnostic Controller 3 3 DC DC Conver...

Страница 8: ...Contents vi...

Страница 9: ...mpliant with SMT version 7 3 MAC PHY and PMD These modules attach directly to the SmartSwitch 9000 FNB backplane delivering up to 400 Mbps of bandwidth The modules use the Intel i960 microprocessor fo...

Страница 10: ...r modules provide MIB support including the following IETF FDDI MIB IETF MIB II a host of Cabletron Enterprise MIBs LANVIEW LEDs The concentrator modules use LANVIEW the Cabletron Systems built in vis...

Страница 11: ...he Concentrator Modules M 1 M 2 M 3 M 4 M 5 M 6 M 7 M 8 1 5 6 4 8 2 3 7 F D D I SMB CPU FNB 9F120 08 FDDI SMB CPU FNB 9F122 12 FDDI 1 4 2 3 5 6 8 7 M 1 M 2 M 3 M 4 M 5 M 6 M 7 M 8 1 5 6 4 8 2 3 7 F D...

Страница 12: ...ng the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at...

Страница 13: ...Grounding receptacle in the lower right corner of the SmartSwitch 9000 Chassis shown in Figure 2 1 4 Remove the MicroLAN Module from the plastic bag Save the bag in the event the module must be reshi...

Страница 14: ...stalling the MicroLAN Module Metal Back Panel Module Guides Module Jack for ESD Wrist Strap Plastic Tab Warning Ensure that the circuit card is between the card guides Lock down the top and bottom pla...

Страница 15: ...Pressing the Reset switch twice within three seconds causes the processor i960 to reset Pressing and holding the switch on for three or more seconds causes the module to shutdown Pressing and holding...

Страница 16: ...ist of an eight position dip switch explained in the next section replaceable PROMs and sockets for RAM These will be used for future upgrades Instructions for installing the components will be suppli...

Страница 17: ...tting the Module Card DIP Switch An eight switch DIP switch is located on the module card as shown in Figure 2 3 and Figure 2 4 The functions of the switches are listed in Table 2 1 Figure 2 4 Locatio...

Страница 18: ...ters which are stored in NVRAM when the module is powered down and remain there until the switch is toggled again 6 Force BootP Download Toggling this switch after pulling the board out of the SmartSw...

Страница 19: ...e Network Bus FNB The FNB consists of two dual FDDI networks FNB 1 and FNB 2 providing up to 400 Mbps of data bandwidth These FDDI networks are 100 ANSI FDDI compliant supporting SMT version 7 3 MAC P...

Страница 20: ...his bus to ensure the validity of SMB 1 In the event a failure is detected on SMB 1 the SMB 10 may be used as an alternate communication channel SMB 10 Bus The SMB 10 is a 10 Mbps management bus locat...

Страница 21: ...r The DC DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network services module The diagnostic controller monitors and controls the operation...

Страница 22: ...Operation 3 4...

Страница 23: ...d may be used as an aid in troubleshooting Shown in Figure 4 1 is the LANVIEW LEDs of the concentrator modules Figure 4 1 The LANVIEW LEDs M 1 1 5 6 4 8 2 3 7 F D D I SMB CPU FNB 9F120 08 FDDI SMB CPU...

Страница 24: ...s LED Color State Description Green Functional Fully operational Yellow Crippled Not fully operational i e one bad port Yellow Green Booting Blinks yellow and green while booting Red Reset Normal powe...

Страница 25: ...he functions of the FDDI Port LEDs are listed in Table 4 4 Table 4 4 FDDI Status LEDs LED Color State Green Link Activity Port enabled Yellow Link No Activity Port enabled Red No link Port disabled Re...

Страница 26: ...LANVIEW LEDs 4 4...

Страница 27: ...EN 55022 Class A VCCI Class I EMC the following requirements EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT Service MTBF MHBK 217E 200 000 hrs MTTR 0 5 hr It is the responsib...

Страница 28: ...gr 3 lb Shipping 1814 4 gr 4 lb Link Distance 9F120 08 Up to 2 kilometers on multimode fiber optic cable as specified by ANSI MMF PMD 9F125 08 40 kilometers max 25 kilometer typical on single mode fib...