SmartSwitch 9500 

9A600 ATM Module

Hardware and Installation Guide

Содержание 9A600

Страница 1: ...9032703 SmartSwitch 9500 9A600 ATM Module Hardware and Installation Guide ...

Страница 2: ......

Страница 3: ...NDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES August 1998 by Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 All Rights Reserved Printed in the United States of...

Страница 4: ...ch case the user will be required to correct the interference at his own expense WARNING Changes or modiÞcations made to this device which are not expressly approved by the party responsible for compliance could void the userÕs authority to operate the equipment VCCI Notice This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology E...

Страница 5: ... Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Mr Ronald Fotino Mr J Solari ____________________________________________________ ______________________________________________________ Full Name Full Name Principal C...

Страница 6: ...Notice iv ...

Страница 7: ...acket Discard PPD 1 5 LANVIEW LEDs 1 5 Related Manuals 1 5 Getting Help 1 6 Chapter 2 Installing the 9A600 Module The Reset Switch 2 3 The Module Card DIP Switch 2 4 Installing an ANIM 2 5 Chapter 3 Operation ATM Cell TrafÞc Flow in the 9A600 3 2 Cabletron Systems ASICs 3 2 i960HD Processor 3 2 System Management Buses 3 3 SMB 1 Bus 3 3 SMB 10 Bus 3 3 System Diagnostic Controller 3 4 DC DC Converte...

Страница 8: ...rating SpeciÞcations 5 1 Environmental Requirements 5 1 Regulatory Compliance 5 1 Service 5 1 Physical 5 2 Device SpeciÞcations 5 2 ANIM SpeciÞcations 5 2 ANIM 21 3 5 3 ANIM 29 3 5 4 ANIM 29 3LR 5 5 ANIM 31 2 5 6 ANIM 39 2 5 7 ANIM 39 2LR 5 8 ANIM 67 2 5 9 ANIM 77 2 5 10 ANIM 22 4 5 11 ...

Страница 9: ...00 chassis Installing ATM Network Interface Modules ANIMs Learning the hardware speciÞcations of the 9A600 and the available ANIMs Prior to installing the 9A600 you should have a working knowledge of ATM networking principles In this document the Cabletron Systems SmartSwitch 9000 chassis is referred to as the SmartSwitch 9500 chassis which indicates a SmartSwitch 9000 chassis with one or more 9A6...

Страница 10: ... modules in the chassis to appear as a single entity with a single IP address and a single ATM address The individual i960 processors are transparent to the network manager and management applications A fully loaded SmartSwitch 9500 chassis appears as a single switch with one IP address and one ATM address The 9A600 is fully compatible with the following ATM Forum speciÞcations Integrated Local Ma...

Страница 11: ...1 3 Overview Figure 1 1 The 9A600 AN AN AN AN 00 ...

Страница 12: ...tal status monitoring PNNI and ILMI conÞguration SmartSwitch 9500 chassis IP address assignment Ability to conÞgure the in band management LAN Emulation Client SmartSwitch 9500 chassis SNMP community names and trap IP address assignment Ability to access Local Management screens of any module installed in the chassis Connectivity The 9A600 can be equipped with a variety of front panel interfaces c...

Страница 13: ...IEW The Cabletron Systems built in visual diagnostic and status monitoring system With LANVIEW LEDs you can quickly identify the device port and physical layer status at a glance Related Manuals The manuals listed below should be used to supplement the procedures and technical data contained in this manual 9A656 04 and 9A600 ConÞguration Guide SmartSwitch 9000 Installation Guide SmartSwitch 9000 O...

Страница 14: ...r network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers Phone 603 332 9400 Internet mail support cabletron com FTP ftp ftp cabletron com Login anonymous Password your email address For additional informatio...

Страница 15: ... module Immediately contact the Cabletron Systems Global Call Center 5 Install the 9A600 module in the chassis by aligning the module card between the upper and lower metal slot guides of any available slot sliding it into the chassis and locking down the top and bottom plastic tabs as shown in Figure 2 1 Take care that the 9A600 slides in straight and properly engages the backplane connectors CAU...

Страница 16: ...Installing the 9A600 Module 2 2 Figure 2 1 Installing the 9A600 AN AN AN AN Circuit Card Card Guides Metal Back Panel Plastic Locking Tab Plastic Locking Tab 00 ...

Страница 17: ...nds causes the module to shutdown Pressing and holding the button again for three seconds restarts the module SNMP management may be used to disable this switch to enhance module security Figure 2 2 The Reset Switch CAUTION Resetting the 9A600 will cause a brief period of system downtime When the interface module is reset the remaining modules go through an initialization process to determine whic...

Страница 18: ...s stored in NVRAM and restores the default passwords Once reset you can use the defaults or enter new passwords 7 Clear NVRAM The module uses NVRAM to store user entered parameters such as IP addresses device name etc To reset these parameters to the factory defaults toggle this switch Once reset you can use the defaults or enter new parameters which are stored in NVRAM when the module is powered ...

Страница 19: ...nectors and the 16 standoff screws for the ATM Network Interface Modules ANIMs Figure 2 3 also shows the location of the Module Card DIP Switch Figure 2 3 ANIM Connector Locations and Module DIP Switch Location ANIM Connectors 4 Standoff Screws 16 2031_04 i960 Processor 1 2 3 4 5 6 7 8 DIP Switch ...

Страница 20: ... Save the screws 3 Lift and remove the coverplate from the top of the front standoffs Figure 2 4 Removing the Coverplate 4 Refer to Figure 2 5 Hold the ANIM by the provided cutouts on the board of the ANIM CAUTION The ANIM and 9A600 module are sensitive to static discharges Use a grounding strap and observe all static precautions during this procedure Failure to do so could damage the ANIM and the...

Страница 21: ...eat steps 2 through 6 to install each one Figure 2 5 Installing an ANIM CAUTION When installing or removing an ANIM make sure to always use the cut outs on the board to handle the ANIM See Figure 2 6 for the location of the cutouts When connecting the ANIM pins to the motherboard connector take extra precaution that the pins do not enter the connector at an angle as this will damage both the ANIM ...

Страница 22: ...Installing the 9A600 Module 2 8 ...

Страница 23: ...TDM Bus Phycsical Connection to Network ATM CELLS ATM CELLS UTOPIA ASICs Separates assembles cell header data Translates headers and provides routing information to move ATM cells out of the TDM TDM ASIC Segments and reassembles data into ATM cells SARI ASIC DATA To SMB 1 10 To Z 80 Processor ROUTING INFORMATION CELL HEADER INFORMATION Queue ASICs Provides translation between the I O ATM bidirecti...

Страница 24: ...ed round robin algorithm TDM Time Division Multiplexer ASIC The TDM ASIC is the central switching engine of the 9A600 The TDM ASIC maintains the connection table gathers statistics and provides Usage Parameter Control UPC policing The TDM ASIC supports up to 128k virtual connections SARI Segmentation and Reassembly Interface ASIC The SARI ASIC is the interface that controls the data ßow between th...

Страница 25: ...e this bus to ensure the validity of SMB 1 In the event a failure is detected on SMB 1 the SMB 10 may be used as an alternate communication channel SMB 10 Bus The SMB 10 is a 10 Mbps management bus located within the SmartSwitch 9500 chassis which is also used for inter chassis communication of modules as well as serving as an out of band management channel into the SmartSwitch 9500 The SMB 10 is ...

Страница 26: ...essor can operate independently of each other if needed they exchange information about each otherÕs status and overall module condition The information gathered by the diagnostic controller is available to the network manager via Local Remote Management and the LCD located on the environmental module The 9A600 has been designed so that in the event of a diagnostic controller fault the modules con...

Страница 27: ...e the status of the module and may be used as an aid in troubleshooting Shown in Figure 4 1 are the LANVIEW LEDs of the 9A600 module Refer to Table 4 1 for the full deÞnitions of 9A600 LED states Figure 4 1 9A600 LANVIEW LEDs System Status SMB Status 2031_09 9A600 ...

Страница 28: ...n Functional Fully operational Amber Fault No database synchronization with the Environmental Module or SMB Off Power off Module powered off CPU Amber Green Booting LED blinks amber and green while booting Red Flashing Failed Fatal error has occurred Off Power off Module powered off ...

Страница 29: ...LANVIEW LEDs of all ANIMs Although there are several types of ANIMs all share the same LANVIEW LEDs Refer to Table 4 2 for the full deÞnitions of ANIM LED states Figure 4 2 ANIM LEDs Table 4 2 ANIM LEDs LED LED Color Status LNK Green Link Off No Link STS Green Port Enabled and OK Amber Standby Red Port Enabled and Error ATM Link ATM Status 2031_10 ...

Страница 30: ...LANVIEW LEDs 4 4 ...

Страница 31: ...Temperature 30 C to 73 C 22 F to 164 F Operating Relative Humidity 5 to 90 non condensing Regulatory Compliance Safety This equipment meets the safety requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EEC Electromagnetic Compatibility This equipment meets the requirements of FCC Part 15 EN 55022 VCCI V 3 CSA C108 8 EN 50082 1 AS NZS 3548 and 89 336 EEC Service MTBF MHBK 217E 200 ...

Страница 32: ...s Processor Intel i960HD RISC processor control Dynamic Random Access Memory DRAM 64 MB FLASH Memory 8 MB ANIM Specifications The 9A600 uses ATM Network Interface Modules ANIMs to provide front panel cable connections The ANIMs should be installed by qualiÞed personnel Refer to the section in Chapter 2 entitled Installing an ANIM for full instructions on the installation process ...

Страница 33: ...2 Mbps The speciÞcations for the ANIM 21 3 are listed in Table 5 1 Figure 5 1 ANIM 21 3 Table 5 1 ANIM 21 3 Specifications Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Multimode Fiber Frame Type SONET SDH Typical Range 2 km Loss Budget TX 17 db to 12 db RX 27 db to 12 db 2031_11 ...

Страница 34: ...5 52 Mbps The speciÞcations for the ANIM 29 3 are listed in Table 5 2 Table 5 2 ANIM 29 3 Specifications Figure 5 2 ANIM 29 3 Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 15 km Loss Budget TX 15 db to 8 db RX 31 db to 8 db 2031_11 ...

Страница 35: ...2 Mbps The speciÞcations for the ANIM 29 3LR are listed in Table 5 3 Table 5 3 ANIM 29 3LR Specifications Figure 5 3 ANIM 29 3LR Parameter SpeciÞcation Number of Interfaces 3 Line Rate 155 52 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 60 km Loss Budget TX 15 db to 8 db RX 31 db to 8 db 2031_11 ...

Страница 36: ... 622 Mbps The speciÞcations for the ANIM 31 2 are listed in Table 5 4 Table 5 4 ANIM 31 2 Specifications Figure 5 4 ANIM 31 2 Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Multimode Fiber Frame Type SONET SDH Typical Range 2km Loss Budget TX 19 db to 14 db RX 26 db to 14 db 2031_12 ...

Страница 37: ...22 Mbps The speciÞcations for the ANIM 39 2 are listed in Table 5 5 Table 5 5 ANIM 39 2 Specifications Figure 5 5 ANIM 39 2 Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 15 km Loss Budget TX 15 db to 8 db RX 28 db to 7 db 2031_12 ...

Страница 38: ...622 Mbps The speciÞcations for the ANIM 39 2LR are listed in Table 5 5 Table 5 6 ANIM 39 2LR Specifications Figure 5 6 ANIM 39 2LR Parameter SpeciÞcation Number of Interfaces 2 Line Rate 622 Mbps Interface Type Duplex SC Media Type Single mode Fiber Frame Type SONET SDH Typical Range 60 km Loss Budget TX 15 db to 8 db RX 28 db to 7 db 2031_12 ...

Страница 39: ...ectors with a line rate of 45 Mbps The speciÞcations for the ANIM 67 2 are listed in Table 5 7 Table 5 7 ANIM 67 2 Specifications Figure 5 7 ANIM 67 2 Parameter SpeciÞcation Number of Interfaces 2 Line Rate 45 Mbps Interface Type BNC Media Type Coaxial Cable Frame Type DS3 Typical Range 185 meters 2 ...

Страница 40: ...nnectors with a line rate of 34 Mbps The speciÞcations for the ANIM 77 2 are listed in Table 5 8 Table 5 8 ANIM 77 2 Specifications Figure 5 8 ANIM 77 2 Parameter SpeciÞcation Number of Interfaces 2 Line Rate 34 Mbps Interface Type BNC Media Type Coaxial Cable Frame Type E3 Typical Range 185 meters 2 ...

Страница 41: ...ors with a line rate of 155 52 Mbps The speciÞcations for the ANIM 22 4 are listed in Table 5 9 Table 5 9 ANIM 22 4 Specifications Figure 5 9 ANIM 22 4 Parameter SpeciÞcation Number of Interfaces 4 Line Rate 155 52 Mbps Interface Type RJ45 Media Type Category 5 UTP Frame Type SONET SDH Typical Range 100 meters ...

Страница 42: ...General Specifications 5 12 ...