5.3
Remote Interface CON3
The Remote Interface CON3 is used to control the hardware of the XENO 4.
The interface has a SUB-D connector, 15 pole.
Pin 15
Pin 9
Pin 8
Pin 1
Figure 34 Remote interface
Pin Signal Name
Description
Activation / active
1
FP24V
Internal operating v24 V, max. 500 mA
to supply external devices
will be switched off at emergency stop
Note :
Using the in24V
(Pin 1) supplying the inputs
requires to connect Pin 1
with Pin 7 and Pin 8 with
Pin 15.
2
Power
Mains voltage applied
Contact between Pin 2 and
Pin 7 closed
3
Shutter
Open
Shutter is open
Contact between Pin 3 and
Pin 7 closed
4
Emission
Laser source is switched on
Keep to the special safety instructions for the
operation under laser class 4
Contact between Pin 4 and
Pin 7 closed
5
Error
There is an error occurred in the control
Contact between Pin 5 and
Pin 7 closed
6
Laser
Ready
Control and laser source are switched on and ready for
marking
Contact between Pin 6 and
Pin 7 closed
7
24V extern External operating v24V, Si T3A
8
GND
0V internal
9
Job Select
Register
active :
User In/Out 1 to User In/Out 4 at CON2 are used
as digital inputs/outputs 1 to 4 in cabLase
inactive :
User In/Out 1 to User In/Out 8 at CON2 are
used as digital inputs/outputs 5 to 12 in cabLase
Note:
Supplying Pin 9 is only evaluated for the initial-
ization of the marking laser (Switch on and Reset)!
When the signal is inactive User in 1 to 8 can be used
to select layouts but objects inside a layout cannot be
selected.
+24V between Pin 9 and
Pin 15
10
Reset
Reset the marking laser
Note :
The restart after reset and initialization of the laser
control may take up to 30 seconds!
+24V between Pin 10 and
Pin 15
11
Laser On/
Off
Active :
Switch on laser source
Conditions for switching on:
Emergency Stop not active, shutter closed
Inactive :
Switch off laser source
+24V between Pin 11 and
Pin 15
12
Pilot Laser
is On
Pilot laser is switched on
Contact between Pin 12 and
Pin 7 closed
13
Open
Shutter
Requirements to open shutter
Conditions for opening:
Emergency Stop not active, interlock closed
+24V between Pin 13 and
Pin 15