15
5
Installation
5.1
Standard values ex factory
i
Note!
The applicator is set up in a standard configuration by the factory. These values guarantee a reliable
operation.
i
Note!
In the case of a customer specific setup with special material the settings can deviate from the standard
values.
In this case the standard values in the setup protocol are as follows.
The factory default settings are:
-
Connected to a cab HERMES Q printer, vertical
-
Pressure value of the compressed air:
0,45 MPa (4,5 bar)
-
Vacuum
-0,06
MPa
(-0,6
bar)
-
Support Air
0,20 MPa (2,0 bar)
-
Pressure value on the exit pressure reduce valve
pad movement
0,20 MPa (2,0 bar)
5.2
Required Space
min. 150 mm
min. 250 mm
print direction
Fig. 8