10.2.3 Trimming parameter
Press the button "TRIMMING" to have access to the trimming parameters.
The following adjustments are available:
1) Trimming function selection.
Trimming option activated (go to the three additional options described below).
Trimming option not activated (go directly to output conveyor parameter).
2) Booklet final length selection, press (2).
Choose the size of the book by entering its final value through the numerical keypad.
Press
"
V
"
to validate.
3)You can also enter the value of the chip (3) in the same way as in 2.
4) Activate or deactivate the blower to evacuate the chips.
"
V
" Validation of the adjustment parameters entered in the different screens.
"
X
" Cancel the last values entered in the defined job.