Operator Manual
BB3002 Page 99
Initial issue: 05/08
Latest revision: 09/14
8 .5 Tips for successful operation:
Keep tank opening to a minimum
•
Use calculated glue usage display to determine when to refill
•
Refill at least
20
minutes before you would run out of adhesive so that the new slug
has sufficient time to begin melting (based on Henkel QR
3317
BR, melt rates vary
strongly with adhesive type)
•
Do not leave the tank lid open unnecessarily long
Keep the time that adhesive is at a high temperature to a minimum
•
Only refill when needed
•
Keep tank temperature
10
-
20
°C lower than the applicator (depending on adhesive
type and usage rate)
If the melter will not used for more than 5* days, the system must be purged with
cleaner!
* depending on adhesive type, how long adhesive was already under temperature and humidity
of environment.
Adjusting Component Temperatures
(Glue QR3317)
Parameter
Value
Description
T° Tank
110°C
Setpoint temperature
T° Hose
120°C
Setpoint temperature
T° Gun
130°C
Setpoint temperature
Note: Valid for Glue type HENKEL QR 3317.
Adjusting Component Temperatures
(Purmelt cleaner 2)
Parameter
Value
Description
T° Tank
150°C
Setpoint temperature
T° Hose
150°C
Setpoint temperature
T° Gun
150°C
Setpoint temperature
Note: Valid for HENKEL PURMELT CLEANER 2.
Содержание BB3002 PUR
Страница 7: ...Operator Manual Page 7 Initial issue 05 08 Latest revision 11 08 Environmental compliance 141...
Страница 9: ...Operator Manual BB3002 Page 9 Initial issue 05 08 Latest revision 11 08 BB3002...
Страница 82: ...Operator Manual BB3002 Page 82 Initial issue 05 08 Latest revision 11 08 5 4 Not available...
Страница 103: ...Operator Manual BBL Page 103 Initial issue 09 13 Latest revision BBL...
Страница 120: ...Operator Manual BBC Page 120 Initial issue 09 13 Latest revision BBC...