Safety Information

WARNING:

 To minimize the risk of potential safety problems, you should follow 

all applicable local and national codes that regulate the installation and operation of 
your equipment. These codes vary from area to area and it is your responsibility to 
determine which codes should be followed, and to verify that the equipment, 
installation, and operation are in compliance with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow 
all applicable codes and standards. We do not guarantee the products described in this 
publication are suitable for your particular application, nor do we assume any 
responsibility for your product design, installation, or operation.

If you have any questions concerning the installation or operation of this 
equipment, or if you need additional information, please call technical support at 
1-800-633-0405 or 770-844-4200.

This publication is based on information available at the time it was printed. At 

Automationdirect.com

® we constantly strive to improve our products and services, so we 

reserve the right to make changes to the products and/or publications at any time without 
notice and without obligation. This publication may also discuss features that may not be 
available in certain revisions of the product.

Copyright 2014, 

Automationdirect.com

 Incorporated/All Rights Reserved Worldwide

Before you begin...

Minimum items required to create a working system:

•  

C-more

 EA9 Touch Panel - 6”, 8”, 10”, 12” or 15” model

•  

C-more

 Programming Software, p/n EA9-PGMSW

•  Personal computer - to run the 

C-more

 programming software

•  

C-more

 USB Programming Cable, p/n USB-CBL-AB15 or Ethernet connectivity between PC 

and Touch Panel

•  Power source: 

C-more

 AC/DC Power Adapter, p/n EA-AC or a dedicated 12-24 VDC 

switching power supply

•  Communications Cable (serial or Ethernet) – to connect the 

C-more

 Touch Panel to your 

controller

1

Unpack and Inspect

2

3

Available Communication Ports

4

Install the Software and Develop a project

6

7

5

8

Additional Help and Support

  •  For product support, specifications, and installation troubleshooting, a Hardware User Manual 

can be downloaded from the On-line Documentation area of the 

AutomationDirect

 Web site 

  •  For software programming help, refer to the 

C-more

 Programming Software on-line embedded 

help.

  •  Refer to demos of the product at: http://c-more.automationdirect.com/software/software_

demo.html

  •  For additional technical support and questions, call our Technical Support team @ 

1-800-633-0405 or 770-844-4200.

Connect 

C-more

 Panel to Computer

Provide Power to 

C-more 

Panel

Access the 

C-more

 Panel Setup Screens

Connect the C-more Panel to a PAC or PLC

Inspect all equipment for completeness. If anything is missing or damaged, 
immediately call the AutomationDirect® returns department @ 1-800-633-0405.

USB Port - Type B

Programming

2

1

3

4

Pin

Signal

1

N.C.

D–

D+

GND

2

3

4

Shield

Shell

USB Port - Type A

USB Device Options

2
1

3

4

Pin

Signal

1

Vbus

D–

D+

GND

2

3

4

Shield

SHELL

Ethernet 10/100 Base-T

PLC Communications,

Programming/Download

1

8

Pin

Signal

1

TD+

TD–

RD+

do not use

2

3

4

Pin

Signal

5

do not use

RD–

N.C.

N.C.

6

7

8

Network Speed LED (Yellow)

On

100M

10M

Off

SD Card Slot 1

SD Card Slot 2

HDMI Port Video Out

Note: Device is not available on Base Feature touch panel EA9-T6CL-R

8

1

15

9

Port 1

PLC Serial Communications

RS-232C / RS-485

Pin

Signal

1

Frame GND

TXD (232C)

RXD (232C)

VCC

2

3

4

5

Logic GND

Pin

Signal

Pin

Signal

6

LE (for DH485)

CTS (232C)

RTS (232C)

RXD+ (422/485)

7

8

9

10

RXD– (422/485)

11

TXD+ (422/485)

TXD– (422/485)

Term. Resistor

N.C.

12

13

14

15

N.C.

1

6

Pin

Signal

1

0V

N.C.

RXD

TXD

2

3

4

+5V

5

0V

6

Port 3

RJ12 Serial Communication

RS-232C

+

Logic Ground

Port 2

Serial Communication

RS-485

Note: Device is only available on touch panels EA9-T12CL and EA9-T15CL.

Link Status LED (Green)

On

Ethernet Linked

No Ethernet Comm.

Off

Comm. Activity

Blinking

Green

•  Purchase the C-more programming software, EA9-PGMSW at 

AutomationDirect.com

. EA9-PGMSW is available on CD or by 

direct download.

•  Install EA9-PGMSW on your PC.

•  Use the software to create a project.

•  Download the project to the 

C-more 

panel from the software via 

Ethernet or USB cable or on USB memory or SD card

Notes regarding Ethernet access to a C-more panel.
If you intend to take advantage of the methods of remote access to the panel, including the web server, PC remote 
access, FTP, iPhone or iPad app, you need to consider the security exposure in order to minimize the risks to your 
process and your C-more panel.

Security measures may include password protection, changing the ports exposed on your network, including a VPN in 
your network, and other methods.  Security should always be carefully evaluated for each installation.

Wire a 

dedicated 12-24 VDC 

power source to the DC connector on the rear 

of the 

C-more

 touch panel, include wiring the ground terminal to a proper 

equipment ground. The recommended power supply is AutomationDirect 
p/n: PSC24-060

•  

or

 install a C-more AC/DC Power Adapter, p/n EA-AC, to the rear of the touch panel and 

wire an AC voltage source of 100-240 VAC, 50/60Hertz, to its AC connector

•  

then

 turn on the power source and check the LED status indicators on the front and rear 

of the 

C-more

 touch panel for proper indication

Power Specifi cations

Model

Specifi cation

EA9-T6CL-R

EA9-T6CL

EA9-T8CL

EA9-T10CL

EA9-T12CL

EA9-T15CL

Power Consumption

16.0W

1.30A @ 12 VDC
0.66A @ 24 VDC

18.0W

1.50A @ 12 VDC
0.75A @ 24 VDC

18.0W

1.50A @ 12 VDC
0.75A @ 24 VDC

21.0W

1.75A @ 12 VDC
0.88A @ 24 VDC

29.0W

2.40A @ 12 VDC
1.20A @ 24 VDC

Internal Fuse 

(non-replaceable)

4.0A

6.3A

CPU Status LED (Green, Orange & Red)

Off

Power Off

Green

Normal - CPU Run State

Red

Memory Error

Blinking Red

Watchdog Timer Error

Blinking Orange

OS Error

Blinking Green

Power Loss Detection

Power LED (Front of Panel)

Color

On

Off

Green

Power On

Power Error

•  Access the Main Menu of the touch panel setup screens by pressing the extreme upper left 

corner of the panel display area for three (3) seconds as shown below.

•  Adjust the time and date for the panel by pressing the Setting button on the Main Menu, 

then press the Adjust Clock button on the Setting screen.

•  Use the right pointing arrows for the time or date display to select the unit to change. Use 

the up and down arrows to increment or decrement the value for the selected unit.

•  Press OK when done to accept the changes to the time and date that is retained in he 

touch panel’s battery backed memory, or press Cancel to exit the Adjust Clock setup screen 
without making any changes.

•  Press the Main Menu button on the Setting screen and then the Exit button on the Main 

Menu screen to return to the application screen.

DL06 PLC

Stride™

Ethernet Switch

10/100 Base-T

(such as SE-SW5U)

H0-ECOM/H0-ECOM100

Ethernet Module

Ethernet CAT5

Cable

C-more

Touch Panel

Auto MDI / MDI-X

Ethernet Port

Ethernet via

Switch

DL06 PLC

H0-ECOM/H0-ECOMM100

Ethernet Module

Ethernet CAT5

Cable

Auto MDI / MDI-X

Ethernet Port

C-more

Touch Panel

Ethernet

•  Connect the serial communications cable between the 

C-more

 touch panel and the PLC

•  

or

 connect the 

C-more

 touch panel and PLC together via an Ethernet switch and Ethernet 

cables (full feature panels only)

•  

or

 use an Ethernet cable directly between the 

C-more

 Ethernet port and the PLC Ethernet 

port (full feature panels only)

EA-2CBL-1

DL-06 PLC

C-more

Touch Panel

Port 2

Port 1

Serial

p

DC power connector

Cutout Template

C-more Panel

Mounting Clips

Quick Start 

Guide

C-more Touch Panel

USB-FLASH

USB Pen Drive

EA-AC

AC / DC Power Adapter

Install Optional Hardware Accessories

•  

Connect

 a USB Programming Cable, such as p/n USB-CBL-AB15, from a USB type A 

port on the PC to the USB type B programming port on the C-more touch panel

•  

or

 connect the 

C-more

 touch panel and PC together either directly or via an Ethernet 

switch, and CAT5 Ethernet cables (full feature panels only)

Ethernet CAT5

Cable

C-more

Touch Panel

Ethernet 

Port

PC

Auto MDI / MDI-X

Ethernet Port

EA-SD-CARD

SD Card

USB-CBL-ABxx

USB Cable

PC

C-more

Touch Panel

USB
Port

USB
Port

Stride™

Ethernet Switch

10/100 Base-T

(such as SE-SW5U)

PC

C-more

Touch Panel

Ethernet

Port

Ethernet CAT5

Cable

Auto MDI / MDI-X

Ethernet Port

USB

Ethernet 

via Switch

Ethernet 

via Cable

EA-AC Tightening Torque

Power supply cable torque

71 - 85 oz-in (0.5 - 0.6 Nm)

Power connector mounting torque

71 - 85 oz-in (0.5 - 0.6 Nm)

Mounting flange screw torque

57 - 71 oz-in (0.4 - 0.5 Nm)

12-24 VDC

+

GND

Equipment

Ground

Recommended DC Supply Fuse

Panel Size

6“ – 10”

12“ & 15”

2.5 A

4.0 A

MDL2-5

MDL4

Rating

ADC p/n

Recommended AC Supply Fuse
3.0A time delay, ADC p/n: MDL3

L

N

G

100 - 240 VAC

50 / 60 Hz

AC Wiring

DC Wiring

Data Sheet: EA9-QSG

C-more EA9 Series Touch Panels

NOTE:  Use 60 / 75 °C copper conductors only,

12 - 24 AWG

EA-x-COV2

Screen Protector

Gasket

Logo Label

ADVERTISSEMENT

:

 Afin de réduire au minimum le risque d’éventuels problèmes de sécu-

rité, vous devez respecter tous les codes locaux et nationaux applicables régissant l’installation 
et le fonctionnement de votre équipement. Ces codes diffèrent d’une région à l’autre et, 
habituellement, évoluent au fil du temps. Il vous incombe de déterminer les codes à respecter 
et de vous assurer que l’équipement, l’installation et le fonctionnement sont conformes aux 
exigences de la version la plus récente de ces codes.

L’omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages 
à l’équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits 
décrits dans cette publication conviennent à votre application particulière et nous n’assumons 
aucune responsabilité à l’égard de la conception, de l’installation ou du fonctionnement de votre 
produit.

Si vous avez des questions au sujet de l’installation ou du fonctionnement de cet équipement, 
ou encore si vous avez besoin de renseignements supplémentaires, n’hésitez pas à nous télé-
phoner au 770-844-4200.

Cette publication s’appuie sur l’information qui était disponible au moment de l’impression. 
À la société 

AutomationDirect

, nous nous efforçons constamment d’améliorer nos produits 

et services. C’est pourquoi nous nous réservons le droit d’apporter des modifications aux 
produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit. 
La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être 
offertes dans certaines versions révisées du produit.

DC-CON Tightening Torque

Power connector screw torque

70.4 oz-in (0.5 Nm)

Power connector mounting torque

56 oz-in (0.4 Nm)

Use 60 / 75°C copper conductors only, 12 - 24 AWG

Отзывы: