BZBGEAR BG-ADAMO-4KND
PRODUCT MANUAL
VISCA Protocol List
VISCA P
ROTOCOL
R
ETURN
C
OMMAND
Ack/Completion Message
Command packet
Note
ACK
z0 41 FF
Returned when the command is accepted.
Completion
z0 51 FF
Returned when the command has been executed.
z= camera a 8
Error Messages
Command packet
Note
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a command
with illegal command parameters is accepted
Command Not Executable
z0 61 41 FF
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
ADAMO T
ALLY
L
IGHT
VISCA C
OMMANDS
Command
Function
Command packet
Note
Red On
Tally Light On
81 01 7E 01 0A 00 02 00 FF
Red Tally Light On
Red Off
Tally Light Off
81 01 7E 01 0A 00 03 00 FF
Red Tally Light Off
Green On
Tally Light On
81 01 7E 01 0A 00 00 02 FF
Green Tally Light On
Green Off
Tally Light Off
81 01 7E 01 0A 00 00 03 FF
Green Tally Light Off
Address:
830 National Drive #140, Sacramento, CA 95834, USA
·
Tel:
+1(888)499-9906
·
Email:
30