background image

CR2032 3V 

Lithium Battery

Remove

Isolation 

Strip

Push Button

• Open up the push button by pushing in the tab on the 

bottom of the push with a small flat screwdriver.

• Remove the isolation strip from the battery 

compartment then it is ready to use.

• When replacing the battery, ensure the battery polarity 

matches the internal markings (“+” facing upwards), 

then press the battery down so that it is sitting firmly in 

its compartment.

Victorian Bell

Insert 4 x 1.5volt alkaline batteries (“C”, UM2 & LR14 

- not included) into the battery compartment at the back 

of the Bell unit, ensuring the battery polarity matches the 

internal markings.

IMPORTANT:

 NOT TO BE USED WITH A TRANSFORMER

Push Button Installation

• Using the holes on the back of push button as a 

template, mark the fixing position for the unit.

• Drill holes and fit wall plugs and secure the push button 

unit to the wall with screws.

• Do not mount it on any metal surface or UPVC door 

frame.

Door Chime Installation

• Drill two holes, fit a wall plugs and screws.

• Leave a gap of 3mm between the screw head and wall.

• Locate the keyhole slots on the back of the chime unit 

over the screws.

Operation

• Press the button on the Push Button unit once, it sends 

a wireless signal to the Bell unit, the Bell unit will sound.

• Operate the Bell unit within the operation range, test it 

before final installation.

Digital Code Set Up

• Press the Push Button once, a new operation code is 

generated randomly and sent to the Chime unit.

• The Bell unit will sound to indicate that a new operation 

code is registered and memorised.

Wire Free Victorian Bell Kit                              SX-60i

Wire Free Victorian Bell Kit                                                                             SX-60i

100m

1

2

3

4

5

6

Push Button unit

Power: 1 x 3volt Lithium battery (CR2032 - included)

Door Chime unit

Power: 4 x 1.5volt alkaline batteries (“C”, UM2 & R14 - not included)

Door Chime Operation

Press the button on the Push Button once, it sends a wireless signal to the Victorian Bell unit and it 

will sound. For repeat sound, press the button again. Hold the button in will 

NOT

 repeat the sound.

Digital Code Set Up 

The Victorian Bell kit is equipped with an advanced random and self-learning operation coding 

ability therefore no setting is needed. Read the following instructions before use.

1. First time operation: 

After battery installation on the Push Button and Victorian Bell units, press the Push Button once 

and it will generate a new operation code randomly and send a wireless signal to the Victorian 

Bell unit. The Bell unit will sound to indicate that a new operation code is registered and 

memorised.

2. Interference from a similar unit operating nearby: 

a) Simply remove the batteries from the Push Button and Victorian Bell units and rest for 10 

seconds, this will erase the memory. 

b) Insert the batteries into the Push Button and Victorian Bell units. Press the Push Button once, 

it will generate a new operation code randomly and send a wireless signal to the Victorian Bell 

and it will sound to indicate that a new operation code is registered and memorised.

3. Front and back door Push Button operation:

a) Remove the batteries from the Push Buttons (Front & Back Door) and Victorian Bell units and 

rest for 10 seconds, this will erase the memory.

b) Insert the batteries into the Push Buttons and Victorian Bell units. Press the front door Push 

Button once, it will generate a new operation code randomly and send a wireless signal to the 

Victorian Bell unit and it will sound to indicate that a new operation code is registered and 

memorised.

c) After, (within 2 minutes) press the back door Push Button once, it will generate a new 

operation code randomly and send a wireless signal to the Victorian Bell unit and it will sound 

to indicate that a new operation code is registered and memorised. The Victorian Bell unit has 

the ability to memorise both operation codes.

d) Test to ensure correct operation before final installation.

Important 

1. Do not mount either unit close to fireplace or expose to high temperatures.

2. Do not expose the Victorian Bell unit to direct sunlight or moisture

3. Always use alkaline battery. Please dispose of old, defective batteries in an environmentally 

friendly manner in accordance with the relevant legislation.

4. Make sure that no naked flame sources, such as lighted candles, should be placed on the unit.

5. The unit should not be exposed to dripping or splashing and no objects filled with liquids, such

as vases, should be placed on the unit.

Byron No.SX60i      Size: A4     Date: 15 Oct 2007

6. 

CAUTION:

 Replace only with the same or equivalent type of battery that is recommended by the 

manufacturer.

7. 

CAUTION:

 Make sure batteries are installed correctly as per the internal markings.

8. 

CAUTION:

 Danger of explosion if battery is incorrectly installed or replaced.

9. 

IMPORTANT:

 There are no serviceable parts in the units, do not attempt to repair it.

User Hints

If the Bell unit does not sound, please check the following:

a) Flat batteries in either Push Button or Victorian Bell units - change the batteries.

b) Wrong battery polarity in either Push Button or Victorian Bell units - re-insert the batteries.

c) Push Button and Victorian Bell units are not on the same operation codes - re-set the code (see 

digital code set up).

d) Units are out of range - Operate the Victorian Bell unit within the operation range.

Specification

Operating Temperature: -10C - +40C

Operating Distance: 100metre (330ft approx. - in open field & at suitable condition)

Selectable Digital Code: Total two hundred fifty six (256) possible digital codes

“Type R2 Device - device where the sound output is created by the initial operation of the control 

and where the period of sound output continues for the designed duration irrespective of condition 

of the control.”

Important:

• Make sure new set of alkaline battery is used in first 

time operation.

• Make sure the batteries are installed properly and 

the battery polarities match the internal markings.

• Change the frequency digital codes if door chime 

activate intermittently for no reason at all (see 

digital set up).

• Do not use the Chime unit with transformer

433MHz

R&TTE

APPROVED

CH Byron Electrical United Kingdom. www.chbyron.com

CH Byron Electrical Ltd

Byron House

34 Sherwood Rd, Astonfield

Bromsgrove, B60 3DR

UK

Tel: 0845 2301231

e: [email protected]

w: www.chbyron.com

‘C’ / LR14’

‘C’ / LR14’

‘C’ / LR14’

‘C’ / LR14’

3mm

Отзывы: