background image

Version 4.0 

 
 
 
 
BYD Battery-Box HV User Manual 

Battery-Box H 6.4/7.7/9.0/10.2/11.5

 

 
 
 
 
 
 
 
 

 

Содержание Battery-Box H 10.2

Страница 1: ...Version 4 0 BYD Battery Box HV User Manual Battery Box H 6 4 7 7 9 0 10 2 11 5 ...

Страница 2: ...6 5 3 1 BCU Interface Introduction Left Side 7 5 3 2 BCU Interface Introduction Right Side 7 5 3 3 BCU Functional Interfaces Definition 7 6 Cleaning and Maintenance 8 6 1 Cleaning 8 6 2 Maintenance 8 6 2 1 Recharge Requirements During Normal Storage 8 6 2 2 Recharge Requirements When Over Discharged 8 7 Compatible Inverter List 9 8 Common Issues and Solutions 9 8 1 Common Issues of BYD Battery Box...

Страница 3: ...ive actions Alterations to the product e g changes or modifications are only permitted with the express written permission of BYD Unauthorized alterations will void warranty claims BYD shall not be held liable for any damage caused by such changes Any use of the product other than that described in the Intended Use section does not qualify as appropriate The enclosed documentation is an integral p...

Страница 4: ...on that must be observed at all times when working on or with batteries To prevent personal injury or property damage and to ensure long term operation of the batteries read this section carefully and observe all safety information at all times WARNING Environmental Requirement Do not expose the battery to temperature above 50 Do not place the battery near any heat sources Do not expose the batter...

Страница 5: ...able Energy may be variant with different inverter brands 2 10 12 will be derating 3 Detailed information refer to BYD Battery Box Compatible Inverter List Model Battery Box H 6 4 Battery Box H 7 7 Battery Box H 9 0 Battery Box H 10 2 Battery Box H 11 5 Battery Module B Plus H 1 28 1 28kWh 24 7kg 5 modules 6 modules 7 modules 8 modules 9 modules Usable Energy1 kWh 6 4 7 68 8 96 10 24 11 52 Max Out...

Страница 6: ...rious Temperatures Ranges Temperature Range Normal Current A 10 0 0 2C 0 12 0 5C 12 50 0 8C Note It will take 2 minutes for the charge current to adjust Discharge Current at Various Temperatures Ranges Temperature Range Normal Current A 10 40 1C 40 50 0 5C No Terms Comment 1 Discharge Battery output power for load 2 Charge To put electricity into battery by charger 3 Full charged Battery had been ...

Страница 7: ...and control The BCU is connected to the battery modules below and to the inverter or BMU above No Name Configuration Energy kWh Voltage V BCU B Plus H 1 28 Base 1 Battery Box H 6 4 1 5 1 6 4 200 282 2 Battery Box H 7 7 1 6 1 7 68 240 338 3 Battery Box H 9 0 1 7 1 8 96 280 394 4 Battery Box H 10 2 1 8 1 10 24 320 451 5 Battery Box H 11 5 1 9 1 11 52 360 500 B Plus H 1 28 BCU Base ...

Страница 8: ...nected to the inverter negative terminal for battery 3 GND Grounding terminal connected to the ground 4 WAN Connected to the Ethernet to complete the functions of communication and remote program update 5 COM Containing RS485 CAN and enable signals outputting 13V power 6 System Air Switch The main switch of system which can be operated manually and has the short circuit protection function Positio...

Страница 9: ...ed regularly according to the following table with 0 5C 12 5A current until 40 SOC after a long time of storage 6 2 2 Recharge Requirements When Over Discharged Please recharge the over discharged batteries in a timeframe that is in accordance to the following table otherwise the over discharged battery modules will be damaged Recharge conditions when in storage Storage Environment Temperature Rel...

Страница 10: ...web page then enter the system s IP address or its host name BYD product serial number without the first three numbers e g product serial number is BYD100171708 00000 then host name will be BYD171708 00000 in the browser and enter the account and password to log in Direct Connection With Network Cable Directly connect the computer to the network interface of BYD Battery Box HV system with the netw...

Страница 11: ...g to the instructions contain in the User Manual Installation Manual and Warranty Letter 1 Please contact our local service provider for technical support after sales service 2 Please download the Warranty Letter via the following website Australian customer www alpspower com au European customer www eft systems de ...

Страница 12: ...stralia Alps Power Pty Ltd Address 14 47 51 Lorraine St Peakhurst NSW 2114 Customer Service Mailbox service alpspower com au Telephone 61 2 8005 6688 Website www alpspower com au Europe EFT Systems GmbH Address Buchenstr 37 97816 Lohr a Main Customer Service Mailbox service eft systems de Telephone 49 9352 8523999 DE 34 91 0602267 ES 39 02 87368364 IT 44 2037695998 UK Website www eft systems de Co...

Отзывы: