BYAN G2M CLASSIC CONTROL BOARD  | Rev. 2019.6.1

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

G2M Classic Control Board 

 
 
 
 
 
 
 
 

Installation and Operators Manual 

 

Specifications: 

 
 

 

Power Supply: 

Single-Phase 115-Volt or 220-Volt 50/60 Hz AC 

 

Motor Power Consumption: 

Up to 550 Watts or 3/4 HP 

 

Electric Lock Output: 

12-Volt DC 1-Amp Maximum 

 

Accessory Power Output: 

24-Volt AC 1-Amp Maximum 

 

Input Power Fuse: 

2-Amp, 250-Volt; 5mm x 20mm Tubular Glass 

 

Motor Power Fuses: 

6-Amp, 250-Volt; 5mm x 20mm Tubular Glass 

 
 
 

 

307.334.2865

 

www.byan.com

 

Fax:  307.334.2028 

Toll Free:  800.223.2926 

P.O. Box 1384 

413 South Linden Street 

Lusk, Wyoming  82225  

BYAN

SYSTEMS INC.

Automatic Gate and Access Control Products

Содержание G2M

Страница 1: ... 550 Watts or 3 4 HP Electric Lock Output 12 Volt DC 1 Amp Maximum Accessory Power Output 24 Volt AC 1 Amp Maximum Input Power Fuse 2 Amp 250 Volt 5mm x 20mm Tubular Glass Motor Power Fuses 6 Amp 250 Volt 5mm x 20mm Tubular Glass 307 334 2865 www byan com Fax 307 334 2028 Toll Free 800 223 2926 P O Box 1384 413 South Linden Street Lusk Wyoming 82225 BYAN SYSTEMS INC Automatic Gate and Access Contr...

Страница 2: ... 2 BYAN G2M CLASSIC CONTROL BOARD Rev 2019 6 1 ...

Страница 3: ...age 15 20x16 Prewired Enclosure with Shadow and Free Exit Bases Wired to 2 Sets of Photobeams Page 16 20x16 Prewired Enclosure with Shadow and Safety Bases Wired to 2 Sets of Photobeams Page 17 20x16 Prewired Enclosure Wired to Miller Edge RBand RB G K10 Sensing Edge and Photobeams Page 18 20x16 Prewired Enclosure Wired to Transmitter Solutions RBand iGAZERKIT UL Sensing Edge and Photobeams Page 1...

Страница 4: ...Y QUALIFIED TECHNICAL PERSONNEL As a Byan Systems gate installer you MUST inform your customer about all safety equipment that should be installed on each job site This is in accordance with your legal liability to your customer Ensure that the protection and warning signaling devices are operational and visible These steps will aid in your defense should you become involved in litigation regardin...

Страница 5: ...ontrolling up to two hp 115 volt or 220 volt AC motors Two different plug in accessory cards are available for the G2M a leaf delay card which comes standard with every board and a traffic light card which is available separately There are three timing potentiometers as well as nine DIP switches incorporated into the board to control different output functions ...

Страница 6: ...er Input Hot 115V Black 220V Red 3 Motor One Close Directional Black 4 Motor One Open Directional Red 5 Motor One Common White 6 Motor Two Close Directional Black 7 Motor Two Open Directional Red 8 Motor Two Common White Commercial Power Hook Up 1 Hook up commercial power to Terminals 1 and 2 of the Power and Motor Run Terminal Strip 2 Connect leads from the Motor No 1 operator to Terminals 3 4 an...

Страница 7: ...e Input Normally Closed People Safe devices such as sensing edges are connected here 9 Safety Common Input Common wires for people and car safety devices are connected here 10 Car Safe Input Normally Closed Car Safe devices such as loop detectors and photo beams are connected here 11 Limit Switch Common Input If limit switches are required the common wires would be connected here 12 Close Limit Sw...

Страница 8: ...he Receiver and the Bulk Head Connector and attach the antenna to the outside of the connector Mag Lock Relay Using IDEC SH2B 05 Base w RH2B UDC12V Relay 1 Connect Terminal 13 on the Relay Base to Terminal 5 of the Accessory Terminal Strip on the board 2 Connect Terminal 14 on the Relay Base to Terminal 6 of the Accessory Terminal Strip on the board 3 Connect Neutral or Ground from the Mag Lock Tr...

Страница 9: ... off and 5 turned on the operators will close as soon as the car safety contacts are cleared 6 See Below See Below 7 Car Safety Contact Operative During Opening When turned on car safety contacts are active during the open and close cycles Input safety for vehicles only works on closing movement unless Switch 7 is set ON The function of DIP switch 6 is changed by the position of the jumper JP1 loc...

Страница 10: ...2 Directional Red 17 Motor 2 Common White TERMINAL BLOCK 3 _________ACCESSORY TERMINALS_______ 24 UNUSED WITH G2M CLASSIC Red 18 24 Volt AC Common Black 19 24 Volt AC Positive Red 20 People Safe Normally Closed White 21 Common Safety 22 Car Safe Blue 23 Common Open Reversing Green 24 Command Open Normally Open Purple 25 Command Reversing Normally Open Orange 6Amps 2Amps 6 Am ps Leaf Delay Card Tra...

Страница 11: ...5 VOLT AC NEUTRAL WHITE 4 GROUND GREEN TB2 OPERATOR MOTOR TERMINALS 5 UN INTERRUPTIBLE 115 VOLT AC BLACK 6 UN INTERRUPTIBLE 115 VOLT AC WHITE 7 GROUND GREEN 3 INTERRUPTED VOLTAGE TERMINALS 8 INTERRUPTED HIGH VOLTAGE 115 VOLT AC BLACK 9 INTERRUPTED HIGH VOLTAGE 115 VOLT AC WHITE TB4 OPERATOR MOTOR TERMINALS 10 GROUND GREEN 11 MOTOR 1 DIRECTIONAL BLACK 12 MOTOR 1 DIRECTIONAL RED 13 MOTOR 1 COMMON WH...

Страница 12: ... Card DIP Switches S1 S2 1 2 3 4 5 6 7 8 POWER TERMINALS Leaf Delay Card Pause Timer Opening Timer Closing Timer JP 1 Test Button ACCESSORY TERMINALS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Transformer 2 Amps 6 Amps 6 Amps Traffic Light Card Flashing Light Card Garage Light Card Daughter Card DIP Switches S1 S2 1 2 3 4 5 6 7 8 POWER TERMINALS Leaf Delay Card Pause Timer Opening Timer Closi...

Страница 13: ...8 24 VOLT AC COMMON BLACK 19 24 VOLT AC POSITIVE RED 19 24 VOLT AC POSITIVE RED 20 PEOPLE SAFE NORMALLY CLOSED WHITE 20 PEOPLE SAFE NORMALLY CLOSED WHITE COMMON SAFETY COMMON SAFETY 22 CAR SAFE BLUE 22 CAR SAFE BLUE 23 COMMON OPEN REVERSING GREEN 23 COMMON OPEN REVERSING GREEN 24 COMMAND OPEN NORMALLY OPEN PURPLE 24 COMMAND OPEN NORMALLY OPEN PURPLE 25 COMMAND REVERSING NORMALLY OPEN ORANGE 25 COM...

Страница 14: ...L i g h t Ca rd L e a f De l a y Ca rd Pause Timer Opening Timer Clos ing Timer G 2M CLASSIC Transformer 6 Amp s 2 Amp s 6 Amps POWER TERMINALS JP1 S1 S2 DIP Switche s ACCESSORY TERMINALS Test Butto n SAFETY DETECTOR BASE SHADOW DETECTOR BASE FREE EXIT DETECTOR BASE Optional Mag Lock Relay Optional Shadow Relay 8 9 TB 3 TB 6 26 27 28 29 30 31 24 25 24 23 22 21 20 19 18 This equipment uses high vol...

Страница 15: ...n g L i g h t C a rd Ga ra g e L i g h t Ca rd L e a f De l a y Ca rd Pause Timer Opening Timer Clos ing Timer Transformer 6 Amp s 2 Amp s 6 Amps POWER TERMINALS JP1 S1 S2 DIP Switche s ACCESSORY TERMINALS Test Butto n SAFETY DETECTOR BASE FREE EXIT DETECTOR BASE Optional Mag Lock Relay 8 9 TB 3 TB 6 26 27 28 29 30 31 24 25 24 23 22 21 20 19 18 This equipment uses high voltage Serious injury or de...

Страница 16: ... t C a rd Ga ra g e L i g h t Ca rd L e a f De l a y Ca rd Pause Timer Opening Timer Clos ing Timer Transformer 6 Amp s 2 Amp s 6 Amps POWER TERMINALS JP1 S1 S2 DIP Switche s ACCESSORY TERMINALS Test Butto n SHADOW DETECTOR BASE FREE EXIT DETECTOR BASE Optional Mag Lock Relay Optional Shadow Relay 8 9 TB 3 TB 6 26 27 28 29 30 31 24 25 24 23 22 21 20 19 18 This equipment uses high voltage Serious i...

Страница 17: ...l a s h i n g L i g h t C a rd Ga ra g e L i g h t Ca rd L e a f De l a y Ca rd Pause Timer Opening Timer Clos ing Timer Transformer 6 Amp s 2 Amp s 6 Amps POWER TERMINALS JP1 S1 S2 DIP Switche s ACCESSORY TERMINALS Test Butto n SAFETY DETECTOR BASE Optional Mag Lock Relay Optional Shadow Relay 8 9 TB 3 TB 6 26 27 28 29 30 31 24 25 24 23 22 21 20 19 18 This equipment uses high voltage Serious inju...

Страница 18: ...E GREEN B ase Connect the common wire of the photobeam to Pin of the S hadow B ase YELLOW 5 Leave all other wire s of the Shadow Base as is Conne ct the wi re of the photobea m to Te rmin al RE D 2 4 Conn ect the wir e of the photobeam to Te rmin al see diagram below BLACK 1 8 Sensing Edge Connection Conne ct the S1 conn ection to the blue wire of the sen sing edg e and the br own wire to th e rad...

Страница 19: ... backplate see diagram to the left Transm itter Solutions iGAZERE Transmitter Sa fe ty 1 Sa fe ty 2 Sa fe ty 1 Ty pe Sa fe ty 2 Ty pe Low P owe r Fre que nc y F Configuration ON Pr og T est 1 Pr og T est 2 Photobeam Connection Disconnect the jumpered connection of the wire from the Shadow Base and the Safety Base GREEN from of the Shadow Base Wire nut the wire of the photobeam to the wire of the S...

Страница 20: ...21 20 19 18 MOTOR CAPS DUPLEX R ECEPT SW ITCH 10 11 12 13 14 15 16 17 TB4 5 6 7 TB 2 L N G TB 1 L e a f De l a y C a rd Paus e Timer Ope ning Timer Closing Timer G2M CLASSIC Tran sform er Tra ffi c L i g h t Ca rd Fl a s h i n g L i g h t Ca rd G a ra g e L i g h t Ca rd 6 Amps 1 2 3 4 5 6 7 8 POWER TERMINALS 2 Amps 6 Amps JP1 S 1 S2 DIP Switches 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ACC...

Страница 21: ...ns TB 5 24 25 24 23 22 21 20 19 18 MOTOR CAPS D UPLEX RECEPT SWITCH 10 11 12 13 14 15 16 17 TB4 5 6 7 TB 2 L N G TB 1 L e a f De l a y C a rd Paus e Timer Ope ning Timer Closing Timer G2M CLASSIC Tran sform er Tra ffi c L i g h t Ca rd Fl a s h i n g L i g h t Ca rd G a ra g e L i g h t Ca rd 6 Amps 1 2 3 4 5 6 7 8 POWER TERMINALS 2 Amps 6 Amps JP1 S 1 S2 DIP Switches 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 22: ...manuals and safety instructions TB 5 24 25 24 23 22 21 20 19 18 MOTOR CAPS D UPLEX RECEPT SWITCH 10 11 12 13 14 15 16 17 TB4 5 6 7 TB 2 L N G TB 1 L e a f De l a y C a rd Paus e Timer Ope ning Timer Closing Timer G2M CLASSIC Tran sform er Tra ffi c L i g h t Ca rd Fl a s h i n g L i g h t Ca rd G a ra g e L i g h t Ca rd 6 Amps 1 2 3 4 5 6 7 8 POWER TERMINALS 2 Amps 6 Amps JP1 S 1 S2 DIP Switches ...

Страница 23: ...EPT SW ITCH 10 11 12 13 14 15 16 17 TB4 5 6 7 TB 2 L N G TB 1 L e a f De l a y C a rd Paus e Timer Ope ning Timer Closing Timer G2M CLASSIC Tran sform er Tra ffi c L i g h t Ca rd Fl a s h i n g L i g h t Ca rd G a ra g e L i g h t Ca rd 6 Amps 1 2 3 4 5 6 7 8 POWER TERMINALS 2 Amps 6 Amps JP1 S 1 S2 DIP Switches 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ACCESSORY TERMINALS Test Button SAFET...

Страница 24: ... all dip switches are in the desired position and making good contact Operators run but there is no piston movement Capacitor bad or not hooked up Bypass screw on operator backed out Check that capacitors are hooked up If one is suspect switch capacitors and see if the problem follows the capacitor Make sure the bypass screw is screwed in and snug Safety devices connected properly but not function...

Страница 25: ... of the second leaf and the closing of the first leaf There are also inputs on the card for Open and Close Limit switches for the second leaf if limit switches are required Adjustable Timers Timer Description Minimum Delay Maximum Delay Open Timer Left 0 Seconds 15 Seconds Close Timer Right 0 Seconds 15 Seconds Board Terminals Installation Instructions To install the leaf delay card simply plug it...

Страница 26: ...osition If the People Safe input is used it is activated when the door is moving The door stops and reverses its movement for two seconds If the People Safe input remains active the alarm relay is activated and the door is paused until the reset alarm is activated If the alarm is not active the next operation is to continue the interrupted operation The stop button interrupts and stops the door in...

Страница 27: ...VOLTAGE TO REDUCE THE RISK OF SEVERE INJURY OR DEATH FOLLOW ALL INSTALLATION INSTRUCTION MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Keep Clear Gate may move at any time without warning Do not allow children to operate the gate or play in the gate area This gate is for vehicles ONLY All pedestrians must use a separate entrance If entrapment protection is set up by constant hold control an automa...

Страница 28: ...if any There are no obligations or liabilities on the part of BYAN SYSTEMS INC for consequential damages arising out of or in connection with the use or performance of these products or other indirect damages with respect to loss of property revenue or profit cost of removal original installation or reinstallation Warranty will be considered void if damage or malfunction was due to improper inadeq...