![BWT RTM HF S-500 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/bwt/rtm-hf-s-500/rtm-hf-s-500_installation-and-operating-instructions-manual_2836688021.webp)
4.1.1 Filter pressure is below the pressure indicated by the blue hand
Clean the filter basket and the skimmers
•
Stop the pump,
•
Put the 6-way multiport valve to "CLOSED",
•
Close the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
•
Open the prefilter and take out the basket,
•
Using a jet of water remove any debris,
•
Put the basket back,
•
Replace the lid of the prefilter making sure that the seal is correctly positioned and that there is enough
water to prime the pump,
•
Clean out the skimmers.
•
Put the 6-way multiport valve to "FILTRATION",
•
Open the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
•
Restart the pump,
•
Purge air from the filter.
This operation should be carried out each time the pool is vacuumed using a brush on a suction line, and
at least once a week.
4.1.2
Filter pressure rises out of the green zone
Backwash the filter
•
Stop the filter,
•
Check the prefilter for debris. (If there is a build-up of dirt clean it out as described above),
•
Put the 6-way multiport valve to the "WASH" position,
•
Open the 1/4 turn valve (F) on the outflow pipe,
•
Turn the motor on,
•
Monitor the water colour through the turbidity sight glass on the 6-way multiport valve.
CAUTION
Cleaning will start after a few seconds. (The water becomes very cloudy)
•
As soon as the water in the turbidity sight glass becomes clear, stop the pump,
•
Put the 6-way multiport valve to the "RINSE" position,
•
Turn the pump on for about 20 to 30 seconds. The purpose of this step is to evacuate any remaining
impurities and settle the sand,
•
Stop the pump,
•
Put the 6-way multiport valve to the "FILTRATION" position,
•
Restart the pump,
•
Close the 1/4 turn valve (F) on the waste line.
•
After back washing, the black hand on the pressure gauge should be realigned with the blue hand, that
is the pressure reading should return to the nominal pressure
•
In the event that the pressure indicated by the pressure gauge does not drop after back washing the
filter once (or even twice) contact your installer.
21/36
2021/01 - Indice de révision : I - Code : 26680
CONSTRUCTION & RÉNOVATION