APPENDIX 1 - ERROR AND WARNING MESSAGES
Error code
Description
P1/P2
Cell operating polarity. The cell automatically inverses its polarity to clean itself.
Lgt
The underwater light is lit
Cov
The cover sensor indicates that the cover is closed. Chlorine production is automatically
reduced to the value set in the Electrolysis menu.
F1
No flow in the installation. Check the flow sensors and make sure that the pressure is correct.
Low
The device cannot reach the desired production level. This could be due to several factors:
- lack of salt
- build up of scale in the cell,
- end of cell service life (check the counter)
- water temperature is low
AL3
Maximum acid dosing time exceeded. Measure the pH, calibration and make sure that the acid
storage tank is not empty. To reset the alarm, press the Back key.