A 1 3 Installation
Failure to follow the installation instructions will
adversely affect the product life of the hoses and
void the warranty in the event of damage.
A
R
correct
correct
correct
correct
wrong
correct
A 1 3 1 Installation instructions
The straight path
A
must measure at least 30 mm.
The bending radius
R
must be at least 50 mm.
Never twist or pull the corrugated hoses.
During installation and the period thereafter, the
hoses must not be subject to any external pressure
or elongation.
►
Only use matching spanners for the hexagon
nuts. Do not use a pipe wrench!
►
Join the water softener and Multiblock with both
corrugated hoses and seal the connections.
Hose for hard water (outgoing arrow on Multiblock,
ingoing arrow on softener).
Hose for soft water (outgoing arrow on softener,
ingoing arrow on Multiblock).
Note:
According to DIN 1988, the flushing water and
overflow hoses must be connected to the sewage
water system at least 20 mm above the highest
waste water level (unimpeded drainage).