Engl
ish
25
C Setting the recharge time
The display has moved to Set Recharge Time Mode. To
operate effectively, your water softener needs to regenerate
periodically
(dependent on the hardness of the supply and amount of water used)
. The
default time of day when this is to occur is 2:00 a.m..
To alter this setting use the
[UP]
[DOWN]
keys.
Pressing the
[SET]
key confirms the entry.
D Setting the Salt Type Mode
The display has moved into Set Salt Type Mode.
If applicable, it can be set with the keys
[UP]
,
[DOWN]
and
[SET]
.
Note!
f
This option “SALt“ is only available on certain models - not standard.
3 Installation
3.1 Installation requirements
National guidelines and regulations:
Observe all applicable installation regulations, general guidelines, hygiene requirements, and technical
specifications. The hard water to be fed into the unit must always meet the specifications of the national
Drinking Water Ordinance or EU Directive 98/83/EC. The total dissolved iron and manganese may
not exceed 0.1 mg/l. The hard water to be fed into the unit must always be free of air bubbles.
Frost protection and ambient temperature:
The installation site must be free of frost and kept free of chemicals, paint, solvents and fumes. The
ambient temperature should not exceed 40°C, even before the machine is started. Please avoid direct
heat sources, e.g. radiators and exposure to sunlight.
General safety:
The rated mains power (see chapter 7 Technical data) and the requisite inlet water pressure must be
present at all times. Failure of water supply during operation will damage the equipment. This must be
installed on-site if required.