Страница 1: ... Mineralized Water FILTER CARTRIDGES AND FILTER HEAD FOR PROTECT Filter system for optimising drinking water Installation and operating instructions AQA drink EN MMWP_NeuesDesign_pink indd 2 05 10 2018 08 54 52 ...

Страница 2: ...rved Tous droits réservés Todos los derechos reservados Tutti i diritti riservati Все права защищены Direitos reservados 0 1 2 3 7 6 5 1 1 dGH 10 ml 4 9 8 1 2 3 5 3 2 1 1 2 3 4 a E A C B D F MM TT TT MM YY MM YY MMWP_NeuesDesign_pink indd 3 05 10 2018 08 54 54 ...

Страница 3: ... Installing the filter system 5 1 Unpacking the filter system 5 2 Fitting the filter bracket 5 3 Determining filter capacity and bypass setting 5 4 Fitting the filter head 5 5 Installing a water meter 5 6 Installing replacing the filter cartridge 6 Service and maintenance 7 Trouble shooting 8 Order numbers 9 Table of filter capacities Explanation of warning notices IWARNING f f Indicates a possibl...

Страница 4: ... at 30 L h 8 US gallons h bar psi 0 10 1 5 0 10 1 5 0 05 0 7 Pressure loss at 60 L h 16 US gallons h bar psi 0 15 2 2 0 15 2 2 0 20 2 9 Pressure loss at 180 L h 48 US gallons h bar psi 0 60 8 7 0 60 8 7 0 50 7 3 Water temperature min max C F 4 to 30 39 to 86 Ambient temperature min max C F 4 to 40 39 to 104 Ambient temperature during transportation storage min max C F 20 to 40 4 to 104 Bed volume ...

Страница 5: ...rom too high a concentration of heavy metals or organic contamination f f To protect the drinking water maintanance and any other work on the filter system has to be carried out considering national directives for drinking water installations e g DIN 1988 EN 1717 and applicable state and local regulations f f If the authorities or the operator of the water supply system release instructions to boi...

Страница 6: ...hat the system limits the passage or growth of bacteria already existing in the incoming water It does not mean that the water leaving the system is safer to drink than the water entering it f f During the filtering process the magnesium content rises slightly If a special low magnesium diet is to be followed BWT recommends to seek medical advice 4 1 Responsibility of the operator The installation...

Страница 7: ...ressure see DIN 1988 Part 2 2 4 4 5 Operation after a break or shutdown Replacement intervals In the event of longer breaks in operation close the shut off valve in the inlet of the filter system After a break in operation exceeding two days weekends vacation rinse the filter system with 4 5 litres 1 1 1 3 gallons of water before reuse Replace the filter cartridge on reaching the capacity stated i...

Страница 8: ...pass setting can be selected based on the general hardness and its application The typical filter capacities are shown in Table T1 last page There are four setting options for the bypass The default bypass setting is 2 The bypass can be set by pressing the button a and twisting the cap on the filter head clockwise or counter clockwise until the required bypass setting is reached and the cap snapps...

Страница 9: ... cartridge counter clockwise into the filter head Open the check shut off valve and check the system for leaks NOTE f f During commissioning the filter has to be purged flushed f f The minimal flushing volume is given in Section 2 2 The volume of purge water is to be dis missed 6 Service and maintenance ICAUTION f f Failure to respect the replacement intervals of the filter cartridge may cause dam...

Страница 10: ...ocedure Section 5 6 Turbid or white water Process related formation of small bubbles of carbo nic acid Turbidity vanishes after 5 minutes Heating element boi ler in the appliance not satisfactorily protected against lime scale Capacity of filter cartridge filter cartridge too small ch ange in water hardness from the water supplier Check total hardness Section 5 3 and filter capacity Fit suitable f...

Страница 11: ......

Страница 12: ...CIOUS LIMESCALE PROTECTION MMWP_NeuesDesign_pink indd 1 05 10 2018 08 54 42 BWT UK Limited BWT House The Gateway Centre Coronation Road High Wycombe Buckinghamshire HP12 3SU 04194 838 100 enquiries bwt uk co uk bwt com ...