DESCRIPTION

 

 

The A

IR

-E

AGLE 

XLT

 

PLUS

 

R

ADIO 

R

EMOTE 

S

TOP 

SWITCH

 IS

 a machine 

mounted R.F.

 

R

EMOTE 

S

TOP 

S

WITCH 

designed to transmit a unique 

STOP signal to the A

IR

-E

AGLE 

XLT

 

PLUS

 

R

ECEIVER

. This system is 

designed to monitor and protect up to 8 dozer operators operating on a 
coal stock pile(s). The large center mounted STOP switch allows easy 
access by the operator. The unit includes a log-in/log-out button for 
system activation and raw coal/clean coal receiver selection. The log-in 
relay channel is user selectable and must be designated for each 
transmitter (see DOZER LOG-IN CHANNEL & RECEIVER LOG-IN 
OPTIONS SELECTION table). Dual color LED's provide a visual 
display of system status, linked receiver, and signal strength. 
 
 

SYSTEM OVERVIEW 

 

Once operator has reached the hazardous area he must log-in to Base 
Receiver 1 or 2 to alert the system to his presence and allow monitoring to 
begin. LED indicators guide this process and provide visual indication of 
various statuses. If at any time the operator pushes the STOP button, the 
stop signal is immediately sent to the receiver to shut down underground 
feeders and alert emergency personnel.  When the operator wishes to 
leave the area, prior to exceeding the range of the transmitter, he must 
push the LOG-OUT button to avoid having an unnecessary shut-down 
signal sent to the receiver. 
 

Note 

– If the RF link is broken or DC power is lost, this will also 

initiate a stop condition at the remote receiver.

 

 

LOGGING IN & OUT TO THE RECEIVER 

 
 

TO LOG IN 

By default, the transmitter is set to log in to 
Receiver #1 only. By using the dip switches on 
SEL1, you can change the set-up to have the 
transmitter log in to Receiver #2 only, or give the 
user the ability to select which receiver to log into. 
(See RECEIVER LOG-IN OPTIONS) When the 
transmitter is set up to give a choice of receivers to 
log into 

(SW6 CLOSED)

, use the following 

procedure: 

Press the LOG-IN BUTTON momentarily to log 
into Receiver #1. The RX.1 LED will blink for 3 
seconds then illuminate solid when link 
established. If the LOG-IN BUTTON is depressed 
a second time during this 3 second period, the unit 
will attempt to log in to Receiver #2 instead and 
the RX.2 LED will blink for 3 seconds then 
illuminate solid when link established 

TO SWITCH 
RECEIVERS 

(SW6 CLOSED)

 

Tap the LOG-IN BUTTON to switch between 

“raw 

coal” and “clean coal” receivers. LED for new 
receiver will blink then illuminate solid with link 
established. Old receiver will log out and 
extinguish LED 

TO LOG OUT 

Press and hold the LOG-IN BUTTON for 3-4 
seconds. Current 

receiver’s LED will blink until log 

out occurs, then extinguish.  LED will not go out 
until the unit has received verification that the 
logout process was successful.  

 

 

CONTROLS & INDICATORS 

 

STOP 
ACTUATOR

 

Latching pushbutton transmits a unique code 
continuously to the remote receiver until the 
operator resets the pushbutton. 

LOG-IN/LOG-OUT 
BUTTON 

A momentary pushbutton used to set 
which receiver the transmitter is to 
link with and alert the system that the 
user is entering or leaving the 
hazardous location 

PWR/SIG/TX 
LED 

Dual color LED used to indicate power (when not 
logged in) and signal strength (when logged in) 

Solid Green 

Indicates Power On (when not logged in) 
Indicates High Signal Strength (when logged in) 

Blinking Green 

Indicates Medium Signal Strength (when logged in) 

Blinking Red 

Indicates Low Signal Strength (when logged in) 

Solid Red 

Indicates STOP button depressed (when logged in) 

RECEIVER 
LEDs 

Green LEDs indicate which receiver the unit is 
logged into 

RX.1 - On solid 

Indicates logged into receiver #1 

RX. 2 

– On solid 

Indicates logged into receiver #2 

RX1 or RX2  - 
Blinking 

Indicates unit is switching receivers 

Отзывы: