BVF Heating Solutions Heato9 Скачать руководство пользователя страница 8

8

Heating active icon 

– if the setting temperature of the thermostat is higher than the current tem-

perature of the room or the heating surface, the heating active icon can be seen. In this case the 

thermostat’s relay makes the circuit and the voltage will get to the output point 4.

Time

 – displays the current time in hh:mm format. Setting of the time is detailed in point 7.

  

button – when momentarily touched, the required temperature value can be raised in the 

turned on condition of the thermostat, or the current value of the factory settings menu point can 

be changed (see details in the programming menu point)
 button

 – when momentarily touched, the required temperature value can be reduced in the 

turned on condition of the thermostat, or the current value of the factory settings menu point can 

be changed (see details in the programming menu point)
 

  button

 – when momentarily touched several times, the comfort, energy-saving and program 

modes of operation can be changed in the turned on condition of the thermostat, or, when depres

-

sed for a longer time, it will enter the programming settings menu.

 

button – by momentarily touching it, the thermostat can be turned on and off.

6. FIX MODES OF OPERATION

When the          or          icon appears on the thermostat’s starting screen in its turned on condition, 

set the temperature to be achieved by using the       or        button. Depending on the real tempe

-

rature of the room (or, depending on the settings, the heating surface) the thermostat switches 

on and the       icon is displayed. Using these modes of operation, the temperature set on the 

thermostat (and to be achieved) will not change until the       or        button is touched. The steady 

temperature values make quick setting possible to provide constant temperatures with time-inde-

pendent, unchanged values. For the          or          modes of operation any temperature values can 

be set by touching the       or        button.

7. PROGRAMMING

The basic purpose of the programming function is to ensure that the thermostat can activate he

-

ating at a time and temperature corresponding to user demands. The use of the programming 

function is recommended in general cases for permanently occupied properties such as family 

homes and apartments with independent heating systems. To access the program mode of ope

-

ration turn on the thermostat, then set it to the         program mode by momentarily touching (if 

necessary, several times) the             button. 
For the settings touch the             

button for a longer time (3 seconds). In the right bottom corner 

of the display the time :pp (:mm) starts flashing. Touching the       or       button set the minute 

value of the current time. 

A tip: by pressing the

       

or

       

button continuously the required value can be reached more quickly; 

one brief touching will change the value with one single minute.

 

For approval and proceeding touch the             

button again briefly. 

Now in the right bottom corner of the display the óó: (hh:) part of the time starts flashing. 

Touching the        or        button set the hour value of the current time.  

A  tip: by pressing the

       

or

       

button continuously the required value can be reached more quickly; 

one brief touching will change the value with one hour. 

For approval and proceeding touch the             

button again briefly. 

Now the number of the days of the week start flashing in the left upper corner of the display. 

Touching the        or        

button set the value of the appropriate day of the week (1 – Monday, 

Содержание Heato9

Страница 1: ...bvfheating com BVF Heato9 Programmable room thermostat DETAILED USER MANUAL...

Страница 2: ...3 2 Technical data dimensions switching current connection 3 3 Installation 4 4 Electrical connection 6 5 Display 7 6 Fix modes of operation 8 7 Programming 9 8 Factory settings menu points 10 9 Faul...

Страница 3: ...ntrolled equipment and make the guarantee null and void 2 TECHNICAL DATA dimensions switching current connection Supply voltage 230V AC 50 60 Hz Relay loadability 3600W 16A recommended max 3200W 14A S...

Страница 4: ...possible install the the heating system at a temperature above 5 C 3 The front and rear panels of the thermostat are connected by a pin type connector Upon removing the front panel this connector sli...

Страница 5: ...5 MOUNTING Electrical box recessed into the wall 65x 55mm horizontal screw locations...

Страница 6: ...the neutral blue wire of the electrical resistance based heating element here 4 Phase output Connect the phase brown conductor of the electrical resistance based heating element here Attention The hea...

Страница 7: ...sponding to the application and the related temperature can be set Setting of the programming is detailed in menu point 7 BVF logo In the upper right corner of the display the logo indicates the stand...

Страница 8: ...rmostat and to be achieved will not change until the or button is touched The steady temperature values make quick setting possible to provide constant temperatures with time inde pendent unchanged va...

Страница 9: ...isplay and the pp hh mm indication starts flashing in the right bottom corner Just like above set the next starting time of the daily program cycle The start of the 2nd program cycle will logically in...

Страница 10: ...ttention Saving of the settings will take place automatically even if no further steps follow and in about 15 seconds the thermostat will turn off In the factory menu after entering it again or settin...

Страница 11: ...a value higher than that even in the case when the room has not reached the desired temperature value A setting recom mended for floor or ceiling heating operated as an independent mode of heating 05...

Страница 12: ...he time specified here If the numerical value of the menu is 30 it means that heating will be switched on again 30 minutes after the temperature drop has stopped An example of how the open window func...

Страница 13: ...h it on again YES The thermostat has switched on the ribbon cable has pressed the front panel when replacing the front panel take care to insert the ribbon cable in the small gap on the rear side NO s...

Страница 14: ...limit values as described in the instructions manual If necessary the setting limit value can be increased If the surface temperature shows an unrealistic value further examination is required If ther...

Отзывы: