BEFORE USE

Read, understand, and follow 

all

 printed materials carefully 

before attempting to assemble or operate these pumps.

NOTICE: 

E-Pumps are shipped dry. Add oil before use.

Electrical Connections:

Compare motor nameplate against power availability

to prevent motor burnout and dangerous electrical

overloading. The motors are wired for 110-125 volts unless 

otherwise specified. 

DANGER:  

Motor, connections and remote on/off switch 

are  energized components containing line voltage.  

Ensure supply is grounded and GFI protected.

Hydraulic Connections:

1. Make sure to use the hydraulic oil specified by the 

manufacturer. Ensure oil level in reservoir is ~ 

2"

 from top 

of reservoir plate, with cylinders retracted and motor off.

2. Use of pressure gauge is strongly recommended. Attach a 

pressure gauge between the pump and cylinder to monitor  

pressure on cylinder.

3. Make sure coupler, hose, valve, gauge are tighten  securely 

to prevent accidental removal of components while in use. 

Hoses 

must

 not be kinked or twisted.

NOTICE

Always secure threaded port connections with non-

hardening pipe thread compound. Take care not to introduce 

compound into port orifices. 

To ensure smooth operation, bleed air from the system by fully 

advancing and retracting the cylinder several times.

4. Do not exceed the rated capacity of the equipment connected 

to the pump. Ensure that 

all hydraulic equipment used 

with this pump is rated at 10,000 psi or greater

OPERATION 

WARNING:  

ALWAYS monitor pressure, force and load 

position.  Pressure may be monitored by means of an 

optional manifold and gauge. Force may be monitored 

by means of a load cell and digital indicator. Correct 

application position can only be determined by the 

operator of the equipment.

1. Check oil level, add oil if necessary.

2. Make sure system fittings and connections are tight and 

leak free.

3. Place control valve lever in the middle (Neutral/Hold) 

position  to prevent accidental lifting or moving of load.

4. To 

start 

the motor:  Toggle the ON/OFF switch located on 

the control box to 'ON' position 

OR

 for momentary use: 

     Leave control box switch in the 'OFF' position and toggle 

remote ON/OFF pendant switch. 

5. It is recommended to use to ON/OFF switch at the 

control 

box

 to let the pump idle for a few minutes before putting 

into operation.

WARNING:  

This pump is for use with a single acting 

cylinder ONLY! Connect one hose from either pump 

oil output port to the input port of a single acting 

application such as a cylinder. Block the unused output 

port securely. This model can not be used with double 

acting cylinders.

6. Use the control valve lever to control the direction of fluid 

flow. These pumps are equipped with a 3-way 3-position 

valve for use with single acting cylinder applications 

ONLY

Refer to Figure 3 below for the flow path.

7. Always monitor the pressure, load and position.

8. Do not exceed the rated capacity of the equipment 

connected to the pump. To 

reduce

 system component 

stress, material fatigue, and the risk of personal injury 

and property damage, 

never

 load a hydraulic application 

(cylinder, spreader, etc.) to more than 80% of its rated 

capacity. 

9. Shift the control valve until the desired pressure, load or 

position is reached. 

Note:

 Do not continue to operate pump 

after cylinder plunger is fully extended or retracted.

10. To 

turn off 

the motor:  Toggle the ON/OFF switch on the 

control box to 'OFF' position. 

11. Depressurize all connections before disconnect. If you 

have any questions, call BVA Technical Service @ (888)-

332-6419.

Position 1 (Advance):

 

Pressured oil flows to port A. 

Position 3 (Retract):

  

Port A returns flow to 

tank.

Position 2 (Hold):

 

Neutral, ports A is 

closed. Hold Position.

Port  A              

Port  A             

Port  A             

P                    T

P                   T

Figure 3- Schematic flow path, valve position of 3-way, 3-position valve for Single Acting Cylinder

Port A

Port B

1

2

3

5

 

!

 

!

 

!

P                   T

Содержание PE0501T

Страница 1: ...nies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 448 2142 E mail sales bvahydraulics com Website www bvahydraulics com Model PEW0501T Model PEW1002T PEW1503T Model PE1002T PE1503T Model PE0501T Maximum Operating Pressure 10 000 PSI for single acting applications only This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety me...

Страница 2: ...IPTION This Pump is engineered to meet most industrial standards for Performance and Safety Its allows quick displacement of hy draulic fluid under no load conditions and easy pumping in loaded conditions This electric hydraulic pump supplies compressed hydraulic fluid to compatible single acting applications ONLY Such applications include rams presses spreaders compactors and crimping machines an...

Страница 3: ...t Stage 2nd Stage PE0501T 1 57 PE0502T 2 62 PE1002T 2 397 36 1 0 63 PE1503T 3 87 PE1505T 5 93 PE1510T 10 115 PE1515T 15 126 PE1525T 25 147 PE3005T 5 100 PE3010T 10 122 PE3015T 15 133 PE3025T 25 154 PEW0501T 1 59 5 PEW0502T 2 64 0 PEW1002T 2 397 36 1 0 70 5 PEW1503T 3 88 5 PEW1505T 5 94 0 PEW1510T 10 116 0 PEW1515T 15 127 0 PEW1525T 25 148 0 PEW3005T 5 101 0 PEW3010T 10 123 0 PEW3015T 15 134 0 PEW3...

Страница 4: ...te this device in an extreme temperature explosive atmosphere or in the presence of conductive liquids Always inspect hoses and connections for damage prior to use Ensure the device is placed on a hard level surface Ensure that application is stable to work on and around Use only approved accessories and approved hydraulic fluid Never attach ANY component not authorized by manufacturer Do not conn...

Страница 5: ... and connections are tight and leak free 3 Place control valve lever in the middle Neutral Hold position to prevent accidental lifting or moving of load 4 To start the motor Toggle the ON OFF switch located on the control box to ON position OR for momentary use Leave control box switch in the OFF position and toggle remote ON OFF pendant switch 5 It is recommended to use to ON OFF switch at the co...

Страница 6: ...Use only good quality hydraulic oil We recommend BVA hydraulic oil F01 F05 Mobil DTE 15M or equivalent To order the oil refer to service parts section Use only the manufacturers recommended hydraulic oil Use of other hydraulic oil may result in pump failure and will void warranty Adding Hydraulic Oil 1 Make sure electric motor is OFF 2 Depressurize and disconnect hydraulic hose from application Sy...

Страница 7: ...Piston Manifold 2 10 511 7 0064 109 O ring 2 11 E05 4 5000 101 Lower Plate Assembly 1 12 E05 4 2000 106 Oil Cap 1 13 b 649 1 0060 407 Bolt M6 10 14 b 601 3 0064 106 Washer 10 15 c d PW4 Control Valve 4 way 1 16 649 1 0095 204 Socket Head Screw 4 17 e E05 4 8000 106 Manifold Safety Valve 1 18 649 1 0063 403 Hex Head Bolt 4 19 f E05 4 6000 106 Gear Pump Assy 1 2 HP 1 20 H23 6 1000 102 Magnet 1 21 E0...

Страница 8: ...g 1 9 a E05 4 4000 106 Piston Manifold 2 10 511 7 0064 109 O ring 2 11 E05 4 5000 101 Lower Plate Assembly 1 12 E10 4 2000 109 Adapter Assembly 1 13 649 1 0060 407 Bolt M6 10 14 601 3 0064 106 Gasket 10 15 E05 4 1000 101 Control Valve 4 way 1 16 649 1 0095 204 Socket Head Screw 4 17 E05 4 8000 106 Block Unloading Assembly 1 18 649 1 0063 403 Socket Head Cap Screw 4 19 E05 4 6001 108 Gear Pump Assy...

Страница 9: ...6 1000 102 Magnet 1 21 E10 3 9005 108 Reservoir 1 22 g 532 3 0160 104 Special Washer 1 23 g E05 6 8008 104 Parker Hex Plug 1 24 E11 6 3006 105 Drain Line 1 25 PEW01 Remote Pendant 1 a E05 3 9940 102 Seal Kit for Item 9 b E05 3 9902 105 Reservoir Bolt Repair Kit c E05 3 9911 106 Valve Assy Repair Kit d E05 3 9910 104 Valve Assy Bolt Repair Kit e E05 3 9980 105 Seal Kit for Item 17 f E05 3 9960 109 ...

Страница 10: ...ld Safety Valve 1 18 649 1 0063 403 Socket Head Cap Screw 8 19 f E15 4 6000 104 Gear Pump Assy 1503 1 19 f E15 4 6002 108 Gear Pump Assy 1505 1 20 H23 6 1000 102 Magnet 1 21 E15 3 9005 104 Reservoir 1 22 g 532 3 0160 104 Drain Plug Assembly 1 23 g E05 6 8008 104 Filter 1 24 E11 6 3008 109 Drain Line 1 25 PEW01 Remote Pendant 1 a E15 3 9940 101 Piston Blk Assy Repair Kit b E05 3 9902 105 Reservoir ...

Страница 11: ...5 6 9007 107 Sleeve Eccentric Bearing 1 9 a E30 4 4000 105 Piston Manifold 4 10 511 7 0064 109 O ring 2 11 E30 4 5000 100 Lower Plate Assembly 1 12 E10 4 2000 109 Adapter Assembly 1 13 b 649 1 0060 407 Bolt 10 14 b 601 3 0064 106 Gasket 10 15 c d E05 4 1000 101 Control Valve 4 way 1 16 649 1 0095 204 Socket Head Cap Screw 4 17 e E05 4 8000 106 Manifold Safety Valve 1 18 649 1 0063 403 Socket Head ...

Страница 12: ...replacement items but are illustrated as a convenient reference of location and position in the assembly sequence Item Part No Description Qty 19 a E30 4 9003 106 Gear Pump Assy PE3005T 1 19 b E31 4 9007 101 Gear Pump Assy PE3010T 1 19 c E31 4 9005 15G Gear Pump Assy PE3015T 1 19 d E31 4 9005 25G Gear Pump Assy PE3025T 1 21 a E30 3 9005 104 Reservoir PE3005T 1 21 b E31 4 9005 208 Reservoir PE3010T...

Страница 13: ...13 SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com ...

Страница 14: ...14 SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com ...

Страница 15: ...15 SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com ...

Страница 16: ...A Hydraulics product fails due to material defect in workmanship you may contact SFA for dis position In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITE...

Отзывы: