1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
3.
Please read specification label on product for
further information and requirements.
4. Do not use in the bathroom.
5.
To reduce the risk of injury, install fan at least
2.1m (7 feet) above the floor.
Pencil and ruler
Flat blade screwdriver
Drill, electric or ratchet drive
3/16″ drill bit
Pliers
Drywall saw or saber saw
WARNING
BV-WF-01 WALL FAN
Installation Guide
WIRING DIAGRAM
CAUTION
TOOLS REQUIRED
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2.
Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction codes and
standards.
4.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating
equipment manufacturer’s guideline and
safety standards such as those published
by the National Fire Protection Association
(NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6.
DO NOT CREATE AN OPENING IN A FIRE-
RATED WALL TO INSTALL THIS FAN. It is
not an exhaust fan, rather it is intended to
direct air from one room to another.
7. This unit must be grounded.
8. The electric service supply voltage must be
120V 60HZ.
USE AND CARE
1
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Description
Grille
Sheet Metal Nut
Sheet Metal Screws
Motor Mounting Bracket
Motor
Blade
Wiring Box Cover
Green Ground Screw
Wiring Box
Housing
Receptacle
Spring
Mounting Brackets
SERVICE PARTS
DISCONNECT ELECTRICAL POWER SUPPLY
BEFORE SERVICING FAN.
Do not turn on the fan when starting a fire in
a fireplace or wood stove until the damper is
thoroughly warm and fully open. Turning the fan
on too soon may draw smoke and flue gases into
the room. Wait until the fire is well established.
Always unplug the fan motor before servicing the
fan. The motor bearings on this fan are lifetime
lubricated and will never need oiling.
Clean the fan blade and motor every six months
by removing the grille, unplugging the motor, and
gently vacuuming the fan blade and motor.
Clean the grille in warm, soapy water. Use a mild
detergent, such as a dishwashing liquid. DO NOT
USE ABRASIVE CLOTHS, STEEL WOOL OR
SCOURING POWDERS.
Please read these instructions carefully before installing, operating, or servicing the fan. Retain this guide for future reference.
AUTOMA
TIC
TERMINAL
SWITCH
FAN HOUSING
JUNCTION BOX
TO 120V/60HZ
BLACK WIRE
WHITE WIRE
GREEN WIRE
1
1
2
3
3
4
5
6
3
8
9
7
10
11
12
13
13