BV BV-WF-01 Скачать руководство пользователя страница 1

1.  For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials 

and vapors.

2.  To avoid motor bearing damage and noisy 

and/or unbalanced impellers, keep drywall 

spray, construction dust, etc. off power unit.

3. 

Please read specification label on product for 

further information and requirements.

4.  Do not use in the bathroom.

5. 

To reduce the risk of injury, install fan at least 

2.1m (7 feet) above the floor.

Pencil and ruler

Flat blade screwdriver

Drill, electric or ratchet drive

3/16″ drill bit

Pliers

Drywall saw or saber saw

WARNING

BV-WF-01 WALL FAN 

Installation Guide

WIRING DIAGRAM

CAUTION

TOOLS REQUIRED

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING:

1.  Use this unit only in the manner intended 

by  the  manufacturer.  If  you  have  questions, 

contact  the  manufacturer  at  the  address  or 

telephone number listed in the warranty.

2. 

Before  servicing  or  cleaning  unit,  switch 

power off at service panel and lock the service 

disconnecting means to prevent power from 

being switched on accidentally. When the 

service disconnecting means cannot be 

locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be 

done by a qualified person(s) in accordance 

with all applicable codes and standards, 

including  fire-rated  construction  codes  and 

standards.

4. 

Sufficient air is needed for proper combustion 

and  exhausting  of  gases  through  the  flue 

(chimney)  of  fuel  burning  equipment  to 

prevent  backdrafting.  Follow  the  heating 

equipment  manufacturer’s  guideline  and 

safety  standards  such  as  those  published 

by the National Fire Protection Association 

(NFPA),  and  the  American  Society  for 

Heating,  Refrigeration  and  Air  Conditioning 

Engineers  (ASHRAE),  and  the  local  code 

authorities.

5.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 

utilities.

6. 

DO NOT CREATE AN OPENING IN A FIRE-

RATED WALL TO INSTALL THIS FAN. It is 

not  an  exhaust  fan,  rather  it  is  intended  to 

direct air from one room to another.

7.  This unit must be grounded.

8.  The electric service supply voltage must be 

120V 60HZ. 

USE AND CARE

1

No.
1

2

3

4

5

6

7

8

9

10

11

12

13

Description
Grille

Sheet Metal Nut

Sheet Metal Screws

Motor Mounting Bracket

Motor

Blade

Wiring Box Cover

Green Ground Screw

Wiring Box

Housing

Receptacle

Spring

Mounting Brackets

SERVICE PARTS

DISCONNECT  ELECTRICAL  POWER  SUPPLY 

BEFORE SERVICING FAN.
Do  not  turn  on  the  fan  when  starting  a  fire  in 

a  fireplace  or  wood  stove  until  the  damper  is 

thoroughly warm and fully open. Turning the fan 

on too soon may draw smoke and flue gases into 

the room. Wait until the fire is well established.
Always unplug the fan motor before servicing the 

fan. The motor bearings on this fan are lifetime 

lubricated and will never need oiling.

Clean the fan blade and motor every six months 

by removing the grille, unplugging the motor, and 

gently vacuuming the fan blade and motor.
Clean the grille in warm, soapy water. Use a mild 

detergent, such as a dishwashing liquid. DO NOT 

USE  ABRASIVE  CLOTHS,  STEEL  WOOL  OR 

SCOURING POWDERS.

Please read these instructions carefully before installing, operating, or servicing the fan. Retain this guide for future reference.

AUTOMA

TIC 

TERMINAL 

SWITCH

FAN HOUSING

JUNCTION BOX

TO 120V/60HZ

BLACK WIRE

WHITE WIRE

GREEN WIRE

1

1

2

3

3

4

5

6

3

8

9

7

10

11

12

13

13

Содержание BV-WF-01

Страница 1: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 2: ...INSTALLATION NOTE Fan can be installed in walls up to 5 1 8 thick For walls less than 4 1 2 thick a trim board frame is needed for spacing see Step 9 Fan can be operated by a wall switch or speed con...

Страница 3: ...move knockout on wiring box using flat blade screwdriver and pliers Fasten electrical cable to wiring box with proper connector for type of wire used Provide 6 leads inside box for electrical connecti...

Страница 4: ...d of plaster or patching compound along edge of housing to fill gap between housing and wall PLASTER FRAME 7 8 Install mounting brackets from inside of fan housing and pull them tightly against back o...

Страница 5: ...ANTY This is a quality product It was made with care and BV offers a limited one year warranty against any manufacturing defects as long as it has been used as directed BV will replace any product sho...

Страница 6: ...e construcci n etc fuera de la unidad de potencia 3 Lea la etiqueta de especificaciones del producto para obtener m s informaci n y requisitos 4 No utilizar en el ba o 5 Para reducir el riesgo de lesi...

Страница 7: ...nstalar en paredes de hasta 5 1 8 de grosor Para paredes de menos de 4 1 2 de grosor se necesita un marco de tablero de compensaci n para el espaciado consulte el Paso 9 El ventilador puede ser operad...

Страница 8: ...ciegos de la caja de cableado con un destornillador de punta plana y unos alicates Sujete el cable el ctrico a la caja de cableado con el conector adecuado para el tipo de cable utilizado Proporcione...

Страница 9: ...orde del alojamiento para llenar el espacio entre el alojamiento y la pared 7 8 Instale los soportes de montaje desde el interior del alojamiento del ventilador y j lelos firmemente contra la parte po...

Страница 10: ...calidad Fue hecho con cuidado y BV ofrece una garant a limitada de un a o contra cualquier defecto de fabricaci n siempre que se haya utilizado seg n las instrucciones BV reemplazar cualquier product...

Отзывы: