Design and Function
Butzbach GmbH Industrietore
Originalbedienungsanleitung SECTIOLITE_V1
24/02/2021
12
5
Design and Function
5.1
SECTIOLITE
®
door types and options
Door type
Description
ST40
SECTIOLITE
®
Standard, door panel height approx. 500mm
ST40T
SECTIOLITE
®
Typ T with a door for people in the centre, door panel height approx.
500mm
ST40S
SECTIOLITE
®
Typ S with door panel separation, door panel height approx. 250mm
Options: Storm, Sprint, Security
Option
Description
Security
ST40S Security version with improved anti-burglary protection pursuant to WK3
Sprint
ST40S Sprint version with higher opening speed
Storm
ST40S Storm version with increased wind resistance
5.2
Functioning of the door system
The SECTIOLITE
®
consists of multiple door panels that are connected to one another with hinges and thus
represent a door panel group. Guide rollers are attached to the header pieces of each door panel, which guide
the entire door in the tracks and keep it in position.
5.2.1 SECTIOLITE
®
movement mechanism
The drive torque transferred through the belt from the drive mechanism is applied to the door through the driver
attached to the bottom door panel and thus enables door movement.
The door can be opened and closed with control buttons or other control devices, e.g. radar detectors, optical
sensors. See the Operation chapter for information about this.
For opening, the door is raised by the drive system and is closed again using gravity (braked by the drive
system).
5.2.2 Variants of SECTIOLITE
®
sectional doors
When opening, door sections are routed under the ceiling and into the interior of the hall (see the middle
drawing). Therefore, a lintel height of at least 350mm is sufficient. The following variants are possible:
Rails guided along the roof (the door follows the roof geometry) - left drawing
Standard version (the door goes up with a 90° deflection) - middle drawing
Vertical rails (the door goes up without any deflection) - right drawing
Note!
The horizontally running tracks must be kept free of deposits, i.e. foreign bodies, dust, ice or similar.
It should be blocked while moving downwards, the belt breakage switch is triggered.