15.1.1 Lower weight limit
Correction weight below a certain limit is normally
shown equal to zero. This limit can be set from 10 g
to 1 g.
At the end of the spin however, by pressing the button
, the weight can be displayed with max resolution
of 1 g, not considering the set lower limit.
IN THE PLANT, THE LOWER LIMIT
FOR THE DYNAMIC WHEEL BAL-
ANCING MODE IS SET TO 5 g.
THE LOWER LIMIT FOR ALL THE
OTHER MODES IS SET TO 7 g.
1
KEY
1 - Lower weight limit in the DYNAMIC program to
display "OK" (5 g default value)
2 - Lower weight limit in the ALU-STATIC program
to display "OK" (7 g default value)
3 - Weights display resolution (5 g default value)
4 - Weight reduction % in the ECO-WEIGHT function
(0 ÷ 200) (100 default value)
2
3
4
- Press the push-button
to shift among the field
to modify.
- Press
or
to modify the highlighted value.
THE BLUE-COLOURED-VALUE
IS THE ACTIVE FIELD AND THE
MODIFIABLE ONE.
15.1.2 Setting adhesive weight dimensions
and static threshold percentage
To ensure the balancing machine precisely calculates
the dimensions and total adhesive weights, set the
height (thickness) and width of the adhesive weights
at your disposal (see
Fig. 51
).
Fig. 51
To carry out this setting, press the icon
. You will
see the following screen:
KEY
1 - Thickness (height) weights (4 mm by default)
2 - Weights width (19 mm by default)
1
2
From this screen page, change the size values of
weights.
- Press the push-button
to shift among the field
to modify.
- Press
or
to modify the highlighted value.
THE BLUE-COLOURED-VALUE
IS THE ACTIVE FIELD AND THE
MODIFIABLE ONE.
LIBRAK380.3DTEC - LIBRAK380P.3DTEC - LIBRAK430.3DTEC - LIBRAK430P.3DTEC