GB
Page 38 of 62
INSTRUCTION, USE AND
MAINTENANCE MANUAL
14.7.2 SPLIT mode
The Split procedure proves useful when the dynamic
unbalance of a wheel is fairly high and the weight to
be fitted is not available, for instance a 100 g weight.
It's possible then to correct the unbalance dividing
the amount of weight into two weights of smaller size.
The Split procedure eliminates errors by using the
“DYNAMIC” program, as for example by manually fit-
ting two 50 g weights close to one another, instead of
only a 100 gr one.
For example:
100 g WEIGHT
TO BE FITTED TO CORRECT
UNBALANCE
TWO SMALLER WEIGHTS (50g)
FITTED MANUALLY
TWO SMALLER WEIGHTS (55g)
USING SPLIT PROCEDURE
Proceed to “DYNAMIC” unbalance measurement dis-
playing by performing a standard wheel spin.
Once detected the unbalance values, verify that the
machine displays the ability to use the "SPLIT" option
(
Fig. 40 ref. 4a
). Press on the icon
to select
directly the procedure "SPLIT" and on the monitor will
be displayed the following screen where you will need
to enter the value of the weights to be applied.
LIBRAK380.3DTEC - LIBRAK380P.3DTEC - LIBRAK430.3DTEC - LIBRAK430P.3DTEC
1297-M021-1_B