INSTRUCTION, USE AND
MAINTENANCE MANUAL
EN
Page 53 of 96
14.2.2 Programs setting through “Measure-
ments acquisition” screen page
From the “Home” page, press the
(
Fig. 40
ref. 1
) button to display "Measurements acquisition"
screen page below:
PRESS THE BUTTON
(
Fig. 40
ref. 1
)
TO DISABLE THE AUTO-
MATIC FUNCTIONS FOR THE
SELECTION OF THE BALANC-
ING PROGRAM OF DISTANCE-
D I A M E T E R C A L I P E R A R M ,
DESCRIBED IN PAR. 14.2.1.
TO BE ABLE TO REUSE THE
AUTOMATIC FUNCTION TO SE-
LECT THE WHEEL BALANCING
PROGRAM WITH GAUGE ARM, IT
IS NECESSARY TO RETURN TO
"HOME" PAGE, BY PRESSING THE
BUTTON
.
The selection of the wheel balancing program is pos-
sible in 2 ways:
- with highlighted program (yellow) by pressing the
or
until you see the desired program.
With this mode only the 11 standard programs can
be selected (DYN, ALU-S, ALU-S1, ALU-S2, STAT,
STAT-1, STAT-2, ALU-1, ALU-2, ALU-3, ALU-4).
IF THE PROGRAM NAME IS NOT
HIGHLIGHTED (YELLOW), PRESS
THE BUTTON
REPEATEDLY
UNTIL THE ABOVE CONDITION IS
REACHED.
- Press the button
to display the following pro-
grams selection screen page:
Use the arrows
and/or
to select the
wished mode (yellow). In this mode you can select
the 11 standard programs (listed above) and special
programs (PAX360, PAX420, PAX460, PAX700).
AFTER YOU HAVE SELECTED THE
DESIRED PROGRAM, USE THE
DISTANCE-DIAMETER CALIPER
AND/OR THE EXTERNAL DATA
GAUGE (IF ANY) TO DETECT THE
MEASURES REQUIRED BY THE
PROGRAM.
WHENEVER THE DISTANCE-DI-
AMETER CALIPER AND/OR THE
EXTERNAL DATA GAUGE (SEE
FIG. 44(IF ANY) IS KEPT IN PO-
SITION FOR A FEW SECONDS
AGAINST THE RIM (UNTIL THE
MACHINE MAKES AN APPRO-
PRIATE SOUND NOTIFICATION),
THE POSITION IS STORED AND
THE VALUES MEASURED IN THE
PRE-ARRANGED FIELDS IN THE
SELECTED WHEEL BALANCING
PROGRAM ARE LOADED.
1301-M001-02
LIBRAK360S - LIBRAK360PS - LIBRAK360WS - LIBRAK360PWS - LIBRAK360WSON - LIBRAK360PWSON - LIBRAK360PWSPRO - LIBRAK360PWS-MC - LIBRAK360PWS-OPEL