EN
Page 46 of 96
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Fig. 36
7. Fit the cone (
Fig. 37 ref. 3
) with the narrowest part
turned towards the wheel.
8. Fit the pressure ring (
Fig. 37 ref. 1
) in the locking
sleeve (
Fig. 37 ref. 2
) and bring everything against
the wheel.
Fig. 37
THE PRESSURE RING (FIG. 37
REF. 1) MUST BE FITTED WITH
THE TEETH OR DISCHARGE SIDE
FACING THE SLEEVE (FIG. 37
REF. 2).
Close the pneumatic chuck by lifting the appropriate
control pedal.
DURING CHUCK OPENING/CLOS-
ING OPERATIONS, BE CAREFUL
TO KEEP YOUR HANDS AND OTH-
ER PARTS OF THE BODY AWAY
FROM THE MOVING CHUCK.
12.3 Correct positioning of ultrasound Run-
out detection device (optional)
To make sure that the rim/tyre “Run-out” detection is
correct, place the device as shown in
Fig.
_
38
:
place
the measurement sensor so that it is turned towards
tyre centre line.
Fig.
_
38
1301-M001-02