INSTRUCTION, USE AND
MAINTENANCE MANUAL
EN
Page 23 of 96
3. Mount the card (
Fig. 23 ref. 2
).
4. Connect ultrasound Run-out cable plug (
Fig. 23
ref. 1
) to the electronic card (
Fig. 23 ref. 2
), as
shown in
Fig. 23
(blue
ref. 4 cable,
brown
ref. 5
cable and
black
ref. 6 cable)
. Connect the ultra-
sound Run-out card (
Fig. 23 ref. 2
) to the wheel
balancer main card, using the provided cable JP18
(
Fig. 23 ref. 3
). Carry out the connection as shown
in
Fig. 23
.
Fig. 23
5. Connect the cables with clamps not to let them
hinder the ordinary operation of the machine.
6. Mount wheel balancer protection guard again.
FOR THE CONNECTIONS, REFER
TO WIRING DIAGRAMS.
9.2.10 Fitting of ultrasound Run-out (option-
al)
1. Fit the ultrasound sensor support plate (
Fig. 22
ref. 1
) to the bracket (
Fig. 22 ref. 2
) using the
bolts (
Fig. 22 ref. 3
), the washers (
Fig. 22 ref. 4
)
and the nuts (
Fig. 22 ref. 5
).
Fig. 22
2. Demount wheel balancer bridge
.
1301-M001-02
LIBRAK360S - LIBRAK360PS - LIBRAK360WS - LIBRAK360PWS - LIBRAK360WSON - LIBRAK360PWSON - LIBRAK360PWSPRO - LIBRAK360PWS-MC - LIBRAK360PWS-OPEL