CAUTION:

   

Verify power is OFF to switch 
before  proceeding.

IMPORTANT NOTES

TOGGLE SWITCH TECHNICAL SPEC.

TOGGLE SWITCH ST YLE: 

STANDARD 2 WAY SWITCH.
RATED AT 10AX 250V~ AC ONLY.

1.

Before  commencing work, isolate  the  mains  power

supply and remove the fuse in  the  fuse box or switch
off the circuit breaker in  the  consumer  unit.

6.

Turn power  back  on.

2.

If unit is to be used as a replacement  for an existing

product, remove existing  unit from its  location and
disconnect the wiring.

5.

To  reduce the  risk of  discolouration or tarnishing,  avoid

installation on wet plaster.

1 GANG 2 WAY  10AX AND TOGGLE SWITCH

2 GANG 2 WAY  10AX AND TOGGLE SWITCH

3 GANG 2 WAY  10AX AND TOGGLE SWITCH

INSTALL ATION

B

UST

ER

ANDPUNC

H

.C

O

M

E

L

E

CT

R

ICI

T

Y

1

G

2

G, 3G & 

4

G SWITC

H

S

KU#

 AUZ-TO-CO-1G-XX-A

**

,  

AUZ-TO-CO-2G-XX-A**

,

AUZ-TO-CO-3G-XX-A**

,  AUZ-TO-CO-4G-XX-A

*

*

4  GANG 2 WAY 10AX AND TOGGLE SWITCH

Note:

 To ensure your toggles operate in the same orientation for on and

o

ff for the top and bottom rows, you need to wire your top row of 

toggles

 

in reverse order to the bottom row. This means your Live will 

now be wired

 

into L2 and your Neutral will be wired into L1.

 

i)

 

Please ensure screws are sufficiently tight to  support the 

product but please do not over tighten  as this may cause 
some deformation to  the plate or damage the screw. 
ii)  Do  NOT  use  a  standard  screw  driver  to  tighten  the  coin 
caps.  This  may  damage  the  cap  and  is  not  covered  under 
warranty. Plastic coin cap tool must be used by hand only.

 Use  a cross  head  electric 

or manual  screwdriver to 
fit the special  countersunk 
screws until tight.

3. 

4a. 

4a. 

 By hand,  screw the  coin 

caps into the end  of the 
screws. Use  the  plastic  coin 
cap tool to fully tighten the 
coin caps i).

4b. 

4b. 

Connect the wires as shown in  appropriate wiring 

diagrams. Use  green/yellow sleeving  on earth conductors 
that are  not insulated. Ensure  terminals are properly 
tightened and no bare wire is visable. Push back unit  into 
moulding  box making  sure conductors are not trapped.

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

L1

L2

L

Please  read before installing.

All wiring and installation must adhere to the latest 
local and national wiring rules - e.g.AS/NZS 3000 in 
Australia & New Zealand;

This product is suitable for indoor use only.

Must be installed by a licensed electrician;
Do not exceed the rated power input 
specification;

1. 

2. 
3. 

4. 

APPROVAL NO. SAA-171697-EA

WARNING:

 The two mounting screws on the 

faceplate must be well tightend to maintain the 
earthing continuity. Check their earthing continuity by 
multimeter before screw on the decorative cap. The 
resistance between the two mounting screws must 
not exceed 0.1 

.

TO EARTH 
TERMINAL
IN BOX

TO EARTH 
TERMINAL
IN BOX

 

NOTE:

 The plate must be earthed at the earth point 