background image

O P E R A T I N G   I N S T R U C T I O N S

B I O   E T H A N O L   F I R E P L A C E S

Содержание fireplace

Страница 1: ...O P E R A T I N G I N S T R U C T I O N S B I O E T H A N O L F I R E P L A C E S ...

Страница 2: ...min 10 in min 5 ft min 10 in min 4 ft ...

Страница 3: ...max 1 5 liters 5 min 3 sec BIOETHANOL ...

Страница 4: ... Choose a proper location for your fireplace Place your Buschbeck bio ethanol fireplace on a solid flat level foun dation where it will not be acciden tally kicked or bumped by any unsus pecting person or animal Place it safely away 4 feet or more from any potentially flammable ob jects Moveable objects curtains drapes etc must not be allowed to come within 4 feet of the fireplace and never above ...

Страница 5: ...gned to be used only with the highest quality pure bio ethanol fuel such as OZOfireTM brand www FuelBarons com available from your fireplace retailer The highest quality bio ethanol fuel should not produce any harmful pol lutants Always refer to the informa tion provided by the supplier of the fuel Study all information available from the fuel supplier Follow all instructions and recommendations f...

Страница 6: ... fire is burning The size of the room is one of the most important matters to consider DO NOT OPERATE THE FIREPLACE IN SMALL OR TIGHTLY ENCLOSED SPACES The information on page 7 may be helpful in determining air exchange requirements UN 1170 Ethanol solution 95 vol completely methylated with 1 methyl ethyl ketone and 10 ppm denatonium benzoate ADR 3 II Water Hazard Classifi cation 1 Keep out of th...

Страница 7: ... air exchange rate in leakproof buildings with standard 3 Complete air exchange in installation room during one hour Air exchange n h Comments 0 0 5 Windows doors closed 0 3 1 5 Window open no shutters 5 10 Window half open user airing habits n h refers to the ratio of air circulation in the roomFor example 0 5 h means that half of the air in the room is replaced each hour USE ONLY GENUINE REPLACE...

Страница 8: ...tice Buschbeck GmbH Friedrich Engels Straße 21 D 51545 Waldbröl Germany www buschbeck indoor de The fire safety and operational safety of the device have been tested by TÜV Süd Industrie Service Munich Test report no W O 1173 00 08 TÜV certified MADE IN EU ...

Отзывы: