5 | Installation
14 / 40
0870201062_RA1000-1600B_Ex_-0007_IM_en
5.2.3 Cooling Water Connection (Optional)
Water-oil heat exchanger without inlet accessories
WHE
CWO
CWI
CWO
TV
PS
MV
WF
CWI
WHE
Water-oil heat exchanger with inlet accessories
WBV
CWI
Cooling water inlet
PS
Pressure switch
CWO
Cooling water outlet
WBV
Water bypass valve
WHE
Water-oil heat exchanger
WF
Water filter
TV
Thermostatic valve
MV
Solenoid valve
The thermostatic valve (TV) is used to control the water flow in order to keep a stable
machine temperature.
The factory default adjustment of the thermostatic valve (TV) is set in position 2 (approx.
75°C oil temperature).
The pressure switch (PS) is used to monitor the presence of water at the cooling system
of the machine.
When the pressure switch detects a pressure lower than 2 bar, the machine must be
stopped.
The water bypass valve (WBV) is used at the first machine start-up. At that moment it
should be open (approx. 90 seconds) to prime the water heat exchanger, afterwards it
should be closed.
The solenoid valve (MV) is used to stop the cooling water circulation when the machine
is not running.
• Connect the cooling water connections (CWI / CWO) to the water supply.
Connection size:
– 19 mm hose (CWI / CWO)
• If necessary, electrically connect the pressure switch (PS), see
sure Switch of Water-oil Heat Exchanger (Optional) [
• If necessary, electrically connect the solenoid valve (MV).
• Make sure that the cooling water complies with the following requirements:
Min. supply capacity
l/min
8
Water pressure
bar
2 ... 6
Supply temperature
°C
+5 ... +35
Required pressure differential across supply
and return
bar
≥
1