Installation | 5
Instruction Manual PUMA WP 0250-2000 D_EN_en
9 | 36
5
Installation
5.1
Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the
●
Make sure to use a suitable backing pump, if necessary seek advice from your Busch
representative
●
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical elements.
●
Make sure that the installation space or location is vented such that sufficient cooling of the
machine is provided.
●
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
●
Make sure that the oil sight glass (OSG) remains easily visible.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally, a maximum of +/- 0.5° in any
direction is acceptable.
●
Make sure that the machine is secured either from the four feet or from the discharge flange.
●
20].
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
For versions WP 1000 D4 and WP 2000 D2:
●
Make sure that the cooling water complies with the requirements, see
11].
If the machine is installed at an altitude greater than 1000 meters above sea level:
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.
5.2
Connecting Lines / Pipes
●
Remove all protective covers before installation.
●
Make sure that the connection lines cause no stress on the machine‘s connection; if necessary use
flexible joints.
●
Make sure that the line size of the connection lines over the entire length is at least as large as
the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a loss of
efficiency. Seek advice from your Busch representative.